Infant Incubator

Infant Incubator photo-1
US$ 900 - 900 MOQ: 1 Pair
Key Specifications
Get Latest Price
Brand Name:
ANTEC
Place of Origin:
China
Model Number:
A-8
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
7 days
Brand Name ANTEC
Place of Origin China
Model Number A-8

STANDARD COMPOSITION:


● Servo Control Mode: air temp;
● Instant Parameter Displaying: set temp, air temp, heat power rate;
● Audible & Visual Alarms: power failure, sensor failure, higher/lower temp, air temperature override, fan failure;
● Power failure reset memory and self-test function;
● Hood with dual slope: 4 hand-ports.

 

SPECIFICATION

POWER
Model A-8-1.....................................................................................................................110 / 120 Vac, 50Hz / 60Hz
Model A-8-2................................................................................................................220 / 240 Vac, 50Hz / 60Hz
Power Input .................................................................................................................................. ≤400VA

Refer to IEC60601-1, this equipment belongs to Class, Type BF.  Its operation is continuous.

ALARM
Power Alarm
Power Failure.................................................Activates if primary power to the Incubator fails or the power wire is accidentally disconnected from the wall receptacle.
Fan Alarm 
Fan Failure.........................................................................................................................Activates if Fan motor malfunctions.
Sensor Alarm
Air Sensor Failure...............................................................................................Air Sensor malfunction, refer unit to service.

Deviation Alarm
High Air Temperature.......................................................Activated if displayed Air Temperature is 1.5
above set point.
Low Air Temperature........................................................Activated if displayed Air Temperature is 2.5
below set point.
Over Temperature Alarm
Over Air Temperature.................................Activated when displayed Air Temperature was approach 38
 in Air Mode.
System Alarm
System Failure ..................................................................................Activated if Temperature Control System malfunctions.


TEMPERATURE CONTROL RANGE AND CORRELATIVE SPECIFICATIONS
Air Temperature.............................................................................................................................................................20
~37
Temperature Rise Time ..................................................................................................................................................... ≤30min
Temperature Variability....................................................................................................................................................... ±0.5

Temperature Uniformity......................................................................................................................................................... ≤1

ENVIRONMENT REQUIREMENT
Environment Temperature
Operation Temperature Range.............................................................................................................................+20
~ +30
Store Temperature Range......................................................................................................................................-40
~ +55
Environment Humidity
Operation Humidity Range............................................................................................................................................30%
~75%
Store Humidity Range...................................................................................................................................................10%
~100%
Atmospheric Pressure Range........................................................................................................................... 700hPa
~1060hPa
OTHER SPECIFICATION
Noise Level Within Hood Environment.................................................................... ≤55dB(Environment noise below 45dB)
Carbon Dioxide (CO2) Level within the Hood.......................................................Less than 0.5% when a mixture of CO2 in air is delivered at 750ml/min at a point 10cm above the center of the mattress.
Air Velocity Over Mattress..................................................................................................................................less than 0.35m/s
Infant Bed Max Load...................................................................................................................................................................10kg
Transfusion Shelf Max Load........................................................................................................................................................2kg

FACTORY DEFAULT SETTINGS
Temperature Control Mode.......................................................................................................................Air Temperature Mode
Air Set Temperature.....................................................................................................................................................................32

Temperature Units............................................................................................................................................................................

NOTE: Open Access Panel or Access Door or the use of supplies or other equipment within the Incubator, which can alter the air flow pattern, may effect temperature uniformity, temperature variability, the correlation of the Incubator temperature reading to center mattress temperature and skin temperature.

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Trading Company
Total Employees
101 - 200 People
Main Markets
North America, South America, Eastern Europe
Location
Yan'an, Shaanxi, China