Home > Products > fire test to building material > BS476-20 test for fire resistance of elements of construction(bs 476-20)
BS476-20 test for fire resistance of elements of construction(bs 476-20)
- 0 Meter / Meters per Month
- T/T L/C D/P D/A
- 7 days
You May Like
-
BS476-22 test for fire resistance of elements of construction(bs 476-22)
-
EN13501-1:2007: Fire classification of construction products and building elements
-
PrCEN TS 45545-2 /EN45545-2 : Fire protection of passenger carrying trains
-
GB 8624 fire test to building material and products-Chinese Standard
-
NF F16-101/102 Fire Resistance Test for Railway Vehicles
-
NFPA 130 Fire test to passenger rail systems
Product Details
Brand Name | Firetc | Place of Origin | China | |
Model Number | BS476-20 |
Product Description
BS476-20 test for fire resistance of elements of construction(bs 476-20)
Firetc fire test center will provide British Standard BS 476-20 fire test for fire resistance of elements of construction.
For more detailed information about BS 476-20,
Please see: /firetesting/show.php?itemid=673
BS 476-20 Fire Resistance Test to Building Material-Standard
Fire Tests on Building materials and structures - Part 20. Method of test for determination of the fire resistance of elements of construction (General principles)
BS 476-20 Fire Resistance Test to Building Material-Standard Brief
The objective of determining fire resistance, as described in the part and the associated parts of BS 476, is to assess the behaviour of a specimen of an element of building construction when subjected to defined heating and pressure conditions. The method provides a means of quantifying the ability of an element to withstand exposure to high temperatures, by setting criteria by which the loadbearing capacity, the fire containment (integrity) and the thermal transmittance (insulation) functions can be adjudged.
A representative sample of the elements is exposed to a specified regime of heating and the performance of the test sample is monitored on the basis of criteria described in the standard. Fire resistance of the test elements is expressed as the time for which the appropriate criteria have been satisfied. The times so obtained are a measure of the adequacy of the construction in a fire but have no direct relationship with the duration of a real fire.
BS 476-20 describes a procedure for a laboratory test for the determination of fire resistance of elements of construction.
BS 476-20 Fire Resistance Test to Building Material-Relative Standard
BS 476:Fire tests on building materials and structures
BS 476-3:Fire tests on building materials and structures. Classification and method of test for external fire exposure to roofs
BS 476-4:Fire tests on building materials and structures - Part 4: Non-combustibility test for materials
BS 476-5:Fire Tests on Building Materials and Structures Part 5: Method of Test for Ignitability
BS 476-6:Fire tests on building materials and structures - Part 6: Method of test for fire propagation for products
BS 476-7:Fire Tests on Building Materials and Structures Part 7: Method of Test to Determine the Classification of the Surface Spread of Flame of Products
BS 476-11:Fire tests on building materials and structures - Part 11: Method for assessing the heat emission from building materials
BS 476-12:Fire tests on building materials and structures- Part 12: Method of test for ignitability of products by direct flame impingement
BS 476-13:Fire Tests on Building Materials and Structures Part 13: Method of Measuring the Ignitability of Products Subjected to Thermal Irradiance
BS 476-15:Fire Tests on Building Materials and Structures Part 15: Method of Measuring the Rate of Heat Release of Products
BS 476-20:Fire Tests on Building Materials and Structures Part 20: Method for Determination of the Fire Resistance of Elements of Construction (General Principles)
BS 476-21:Fire Tests on Building Materials and Structures Part 21: Methods for Determination of the Fire Resistance of Load bearing Elements of Construction
BS 476-22:Fire Tests on Building Materials and Structures Part 22: Methods for Determination of the Fire Resistance of Non- Load bearing Elements of Construction
BS 476-23:Fire Tests on Building Materials and Structures Part 23: Methods for Determination of the Contribution of Components to the Fire Resistance of a Structure
BS 476-24:Fire Tests on Building Materials and Structures Part 24: Method for Determination of the Fire Resistance of Ventilation Ducts
For more detailed information about British Standard BS 476-20fire test for fire resistance of elements of construction.Please contact on firetest@firetc.com.
Learn more from for English or for Chinese
Contact Us
- Firetc Fire Test Center
- Contact nameGong Liu Chat Now
- Phone86-0592-5056213
- AddressPowercenter, No.301 Jiahe Road, Xiamen, China, Weihai, Shandong
Product Categories
Fire test to Aircraft Material | fire test to building material | fire test to railway components | Fire test to Upholstered Furniture and Textile |
New product |
New Products
-
Fire Test to Upholstered Furniture and Textile – Standard List
-
ISO 4589-2:Oxygen Index Test to Plastics Material
-
IEC 60695-11-10(UL 94)Fire hazard testing to Plastics Material
-
FAR25.853 Vertical Flammability Test for Aircraft Material
-
BSS7239 Toxicity Test to Aircraft material-Boeing Standard
-
Airbus Standard:ABD0031
-
FAR 25.853: Seat Flammability Test to Aircraft Material
-
BS EN ISO 12952: Fire Test to Bedding items
-
16 CFR 1632 Flammability Test to mattresses and mattress pads
-
BS 7177: Flame retardant test to mattresses, divans and bed bases
-
BS 476-7Standard Test Method for Surface Burning Characteristics of Building Materials
-
BS 6853 fire test to locomotive
Popular Searches
- Mgo Wall Board
- 1.4g
- calcium silicate products
- Cement Board Ceiling
- animals siding
- calcium silicate ceiling
- better economics
- board economics
- bird nest crystal
- bird nest wood
- crystal dubai
- Silicate Board Ceiling
- case economics
- cases economics
- ceiling economics
- class economics
- class magnesium
- colorful ivory
- Colorful Ivory Set
- contacts economics
- crystal economics
- crystal siding
- cs boards
- cs board
- cycle ceiling
- calcium silicate tile
- dust it
- decor economics
- development economics
- economics phones
Recommended Products
- Factory direct supply of roof fireproof insulation board, wall fireproof insulation board, and glass magnesium insulation board
- Residential prefabricated firewall panels and residential prefabricated houses
- RWS tunnel board and tunnel fireproof board manufacturer
- Factory direct supply of SIP sandwich panels, glass magnesium sandwich insulation panels, and movable room insulation wall panels
- Magnesium oxide board manufacturer
- Hot selling calcium silicate 500 * 25 calcium silicate board
- Shandong calcium silicate fireproof board
- Laizhou high-temperature resistant asbestos free calcium silicate board fiber reinforced insulation brick
- Chinese non asbestos calcium silicate manufacturer
- 1050 ° C high temperature resistant insulation silicon calcium board
- Manufacturer: Calcium silicate insulation board, insulation board, high-temperature resistant tube shell
- High density calcium silicate insulation manufacturer calcium silicate tube shell
Find Similar Products By Category
- Construction & Decoration > Fire Retardant & Fireproof Material > Fireproof Board
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Gong Liu
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email