LC1-D(CJX2 ) AC Contactor
1. Application
CJX2 series AC Contactor is suitable for using in the circuits the rated voltage up to 660V AC 50Hz or 60Hz, rated current up to 95A, for making & breaking, frequently starting & controlling the AC motor. Combined with the auxiliary contact block, timer delay & machine- interlocking device etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter. With the thermal relay, it is combined into the electromagnetic starter. The Contactor is produced according to IEC 60947-4, GB14048-4. Standard control voltage
|
Voltage |
50Hz |
60Hz |
50/60Hz |
|
24 |
B5 |
B6 |
B7 |
|
42 |
D5 |
D6 |
D7 |
|
48 |
E5 |
E6 |
E7 |
|
110 |
F5 |
F6 |
F7 |
|
220 |
M5 |
M6 |
M7 |
|
230 |
P5 |
- |
P7 |
|
240 |
U5 |
U6 |
U7 |
|
380 |
Q5 |
Q6 |
Q7 |
|
400 |
V5 |
- |
V7 |
|
415 |
N5 |
- |
N7 |
|
440 |
R5 |
R6 |
R7 |
|
500 |
S5 |
- |
- |
|
660 |
Y5 |
- |
- |
2. Specification
|
Type |
CJX2-09 (LC1-D09) |
CJX2-12 (LC1-D12) |
CJX2-18 (LC1-D18) |
CJX2-25 (LC1-D25) |
CJX2-32 (LC1-D32) |
CJX2-40 (LC1-D40) |
CJX2-50 (LC1-D50) |
CJX2-65 (LC1-D65) |
CJX2-80 (LC1-D80) |
CJX2-95 (LC1-D95) |
||
|
Rated working current (A) |
AC3 |
9 |
12 |
18 |
25 |
32 |
40 |
50 |
65 |
80 |
95 |
|
|
AC4 |
3.5 |
5 |
7.7 |
8.5 |
12 |
18.5 |
24 |
28 |
37 |
44 |
||
|
AC3 capacity of three-phase squirrel-cage motor AC3(kW) |
220/230V |
2.2 |
3 |
4 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
25 |
|
|
380/400V |
4 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
37 |
45 |
||
|
415V |
4 |
5.5 |
9 |
11 |
15 |
22 |
25 |
37 |
45 |
45 |
||
|
440V |
4 |
5.5 |
9 |
11 |
15 |
22 |
30 |
37 |
45 |
45 |
||
|
500V |
5.5 |
7.5 |
10 |
15 |
18.5 |
22 |
30 |
37 |
55 |
55 |
||
|
660/690V |
5.5 |
7.5 |
10 |
15 |
18.5 |
30 |
33 |
37 |
45 |
45 |
||
|
Rated heat current (A) |
20 |
20 |
32 |
40 |
50 |
60 |
80 |
80 |
125 |
125 |
||
|
Electrical life |
AC4X104 |
20 |
20-15 |
20-7 |
15-7 |
15-7 |
10-7 |
7 |
7-6 |
7-5 |
7-5 |
|
|
AC3X106 |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
1.6 |
1.6 |
1.6 |
||
|
Mechanical lifeX106 |
20 |
20 |
20 |
20 |
20 |
20 |
50 |
20 |
10 |
10 |
||
|
Number of the contact |
3P+NO |
|||||||||||
|
3P+NC |
||||||||||||
|
Matched auxiliary contact type |
LA1-DN02(2NC),LA1-DN11(1NO+NC),LA1-DN20(2NO),LA1-DN22(2NO+2NC),LA1-DN40(4NO,LA1-DN04(4NC),LA1-DN13(1NO+3NC),LA1-DN31(3NO+1NC) |
|||||||||||
|
Matched time delay auxiliary contact type |
Time delay after power on:LA2-DT0(0.1-3S),LA2-DT2(0.1-30S),LA2-DT4(10-180S),Time delay after power off:LA3-DR0(0.1-3S),LA3-DR2(0.1-30S),LA3-DR4(10-180S) |
|||||||||||
Send Inquiry to This Supplier
You May Also Like
-
ABB A145-30-11 A1453011 220VACNegotiableMOQ: 1 Piece
-
Air Coil Circuit Electric Rating ac Magnetic Contactor PriceNegotiableMOQ: 1
-
FC-1UL ContactorNegotiableMOQ: 1 Piece
-
FUSE CLIPSNegotiableMOQ: 1 Piece
-
ContactorNegotiableMOQ: 1 Piece
-
Terminal ConnectorNegotiableMOQ: 1 Piece
-
Brand Groups Sportswear Uniforms Digital Print Custom (factory Direct)NegotiableMOQ: 1 Piece
-
ContactorsNegotiableMOQ: 1 Piece
-
Yellow Chiffon Belly Dance Practice Costumes With Golden Coins , Belly Dancing WearNegotiableMOQ: 1 Piece
-
Gold Finger 2 Layers OSP Surface Treatment Flexible Printed Circuit Board Assembly ServiceNegotiableMOQ: 1 Piece