Product Origin:
Brand Name:
Price Terms:
Payment Terms:
Certification:
Description:Specifications: 1) Name: 1 pole definite purpose contactor 2) Model number: HLC-1N 3) Contact: a) Arrangements: 1 pole N.O. without shunt b) Structure: double make contacts c) Materials: silver cadmium oxide (10% to 30Amp 13% 40Amp) d) Max. loading rating: see contact rating chart 4) Coil: a) Coil voltage: 50/60Hz, see coil rating chart b) Nominal resistance: see coil rating chart c) Nominal inrush power: 5VA@60Hz, 6VA@50Hz d) Coil temperature rise: 65oC max. e) Class of insulation: 130oC class B 5) Operation: a) Must operate voltage: 85% of nominal coil valtage or less (24VAC=75% or less) b) Must release voltage: 10% to 60% of operate voltage c) Initial operate time: 20ms typical d) Initial release time: 10ms typical e) Bounce time: 0 to 10 ms typical 6) Environment: a) Temperature range: storage and operating -40 - 65oC 7) Initial dielectric strength: a) Between contacts and coil: 2,500VAC b) Between poles: 2,500VAC c) Between open contacts: 2,500VAC 8) Mechanical data (power pole termination: wire size, tightening torque): a) #10-32 screw: 16 - 8 AWG, 22Ibf.-in.(2.49Nm) b) Box lug: 14 - 4 AWG, 40Ibf. -in. (4.52 Nm) 9) Coil termination: dual 0.250 quick connects (6.35mm) 10) Unit weight without optional cover: 7oz (200g/m) 11) Life expectancy: depends upon duty cycle, load, and environmental conditionals 12) Mechanical life: a) Design requirement AR1780 = 500,000 operations b) Min test requirement = 1,000,000 operations at 60 operations per minute, 50% Duty cycle, 150 F and 110% of nominal coil volatage 13) Electrical life test results: a) 40 and 50 RLA (resistive load) b) 250,000 operations make, carry and break 100% pf. 600VAC 30 FLA rated c) 200,000 operations make LRA 40 to 50% pf., break 125% FLA 75 to 80% pf.@240VAC d) 250,000 operations make, carry, break 75 to 80% pf.@240VAC e) 250,000 operations make, carry, break 75 to 80% pf.@600VAC 40 FLA rated f) 100,000 operations make LRA 40 to 50% pf., break 125% FLA 75 to 80% pf.@240VAC g) 250,000 operations make, carry, break 75 to 80%pf.@240VAC h) 300,000 operations make, carry, break 75 to 80%pf.@600VAC
Send Inquiry to This Supplier
You May Also Like
-
ABB A145-30-11 A1453011 220VACNegotiableMOQ: 1 Piece
-
Air Coil Circuit Electric Rating ac Magnetic Contactor PriceNegotiableMOQ: 1
-
FC-1UL ContactorNegotiableMOQ: 1 Piece
-
FUSE CLIPSNegotiableMOQ: 1 Piece
-
ContactorNegotiableMOQ: 1 Piece
-
Terminal ConnectorNegotiableMOQ: 1 Piece
-
Brand Groups Sportswear Uniforms Digital Print Custom (factory Direct)NegotiableMOQ: 1 Piece
-
ContactorsNegotiableMOQ: 1 Piece
-
Yellow Chiffon Belly Dance Practice Costumes With Golden Coins , Belly Dancing WearNegotiableMOQ: 1 Piece
-
Gold Finger 2 Layers OSP Surface Treatment Flexible Printed Circuit Board Assembly ServiceNegotiableMOQ: 1 Piece