Specifications
LCD display with three color backlight with 2 x analog outputs and 2 stages alarm. Preset two stages alarm points.Factory price gas monitoring for ozone
Gas Detected | Ozone |
Sensing Element | Electrochemical gas sensor |
Sensor lifetime | >2 years, removable |
Temperature Sensor | NTC 5K |
Humidity Sensor | HS series capacitive sensor |
Power Supply | 24VAC/VDC (power adaptor selectable) |
Power Consumption | 2.8W |
Response Time | <50s @T90 |
Signal Update | 1s |
Warm up Time | <60 seconds |
Ozone Measuring Range | 0~5000ppb (0-5ppm)( 0~9.81mg/m3) |
Display Resolution | 1ppb (0.001ppm) (0.01mg/ m3) |
Accuracy | ±0.01ppm + 10% reading |
Nonlinear | <1%FS |
Repeatability | <0.5% |
Zero Drift | <1% |
Alarm | Buzzer and Yellow or Red backlight switch |
Display | Green-normally, Orange – first stage alarm, Red- second stage alarm. Ozone alarm points can be preset. |
Temperature/humidity Measuring Range | -20°C~60°C (-4°F~140°F)/0~99%RH |
Analog Output | 0~10VDC(default) or 4~20mA linear output selectable |
Analog Output Resolution | 16Bit |
Relay dry contact Output | Two dry-contact outputs Max, switching current 3A (220VAC/30VDC), resistance Load |
Modbus Communication Interface | Modbus RTU protocol with 19200bps(default) Other bps rate selectable in order 15KV antistatic protection |
Working Condition | -20°C~60°C (-4°F~140°F)/ 0~ 99% RH |
Storage Conditions | -40°C~70°C (-40°F~158°F)/ 0~ 95% RH |
Net Weight | 190g |
Dimensions | 130mm(H)×85mm(W)×36.5mm(D) |
Installation Standard | 65mm×65mm or 85mmx85mm or 2”×4” wire box |
Interface Connection (Max) | 9 terminals |
Wiring Standard | Wire section area<1.5mm2 |
Manufacturing Process | ISO 9001 Certified |
Housing and IP class | PC/ABS fireproof plastic material, protection class: IP30 |
Compliance | EMC Directive 89/336/EEC |
1.Ozone monitor designed for real time monitoring ambiance ozone level and temperature
2.Gentlest shape and convenient structure
3.Trusty quality with lower prices
4.Particular LCD display with three color backlights
5.LCD displays ozone level and temperature measurements
6.Electrochemical ozone sensor with 0~5ppm (0~5mg/m3), high sensitivity
7.Two stages alarm preset
8.Both alarm way: buzzer alarm and backlight
lours switch
10.Provide up to 010V analog output and 2 relay dry contact outputs
11.Humidity measurement and display optional
12.RS485 communication interface, 15 KV antistatic protection
13.Provide two easy methods for calibration and setup alarm points by end users: infrared remote controller and a software via RS485
Send Inquiry to This Supplier
You May Also Like
-
DANFOSS Controller MCX08M080G0310NegotiableMOQ: 1 Piece
-
Pen Ventilated Variable Frequency Phase-shifting Transformer/Class H Multi-winding Dry Type Rectifier TransformerNegotiableMOQ: 50 Sets
-
CEEG China Amorphous Core Dry-Type Transformer - Ultra Low No-Load Loss (Up to 70% Savings), High Efficiency, Custom KVANegotiableMOQ: 1 Unit
-
ABB DSTDN020 3BSE003238R1NegotiableMOQ: 1 Piece
-
WOODWARD 8901-457 – Industrial Control Module for Engine/Turbine Protection and Speed ManagementNegotiableMOQ: 1 Bag
-
ABB 1SBL177001R1101 AF16-30-01-11 ContactorNegotiableMOQ: 1 Piece
-
Original Honeywell Burner Ignition Controller TBC2800A1000 for Burner Spare PartNegotiableMOQ: 1 Piece
-
100% New Omron PLC Digital Input Unit CJ1W-ID211 StockNegotiableMOQ: 1 Piece
-
HONEYWELL 1PC Honeywell TMG740-3 Mod.43-35 Controller TMG7403 New Expedited Shipping Honeywel Tmg 740 -3NegotiableMOQ: 1 Piece
-