Home > Electrical & Electronics > Sensor > Pressure Sensor > CO2 Controller for Ventilation System

CO2 Controller for Ventilation System

CO2 Controller for Ventilation System photo-1
Negotiable MOQ: 1 set (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Place of Origin:
Beijing, China
Brand Name:
Tongdy
Model Number:
F2000IAQ-CO2-30XX/50XX
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin Beijing, China
Brand Name Tongdy
Model Number F2000IAQ-CO2-30XX/50XX

Specifications

1.CO2 monitor with temperature and humidity detection.
2. GE/Telaire NDIR CO2 sensor is inside with 15 years lifetime

        CO2 controller for ventilation system

CO2 controller for ventilation system

Gas detected

Carbon Dioxide (CO2)

Sensing element

Non-Dispersive Infrared Detector (NDIR)

Temperature sensor

NTC

Humidity sensor

HS series capacitive sensor

Temperature dependence

0.2% FS/°C

Temperature correction

Self compensation

Power supply

24VAC/VDC, or 100~240VAC, 60HZ, selectable with the order

Consumption

3.5 W max. ; 2.5 W avg.

Accuracy@25°C(77°F)

±40ppm + 3% of reading

Stability

<2% of FS over life of sensor (15 yr typical)

Calibration interval

ABC Logic Self Calibration Algorithm

Non linearity

<1% of FS

Pressure dependence

0.13% of reading per mm Hg

Altitude calibration

Programmable from 0-9,900m in 100m increments

Response Time

<2 minutes for 90% step change

Signal update

Every 2 seconds

Warm up time

2 hours (first time)

2 minutes (operation)

CO2 measuring range

0~2,000ppm (default)

0~20,000ppm, programmable selection

0~50,000ppmt

CO2 setting & Display resolution

1ppm

Temperature measuring/ setting range

0~50°C(32~122°F)/ 5~45°C(41~113°F)

Humidity measuring/setting range

0~99%RH/ 5~95%RH

Analog output

0~10VDC linearized output or PID control output, selectable by end users

Output resolution

10Bit

Relay output

One or two dry contact outputs with programmable selection to control CO2, temperature, humidity

Rated switching current: 3A(220VAC/30VDC), resistance load

Communication interface

RS-485, 9600/14400/19200(default)/28800 or 38400bps (programmable selection), 15KV antistatic protection, 3 independent base address, max network node 64

Flow rates

Diffusion version 80 ~ 120 cc/min

Flow through version 40~50cc/min

Operation conditions

0~50°C(32~122°F); 0~95%RH,

Storage conditions

-10~60°C(14~148°F)/5~90%RH non condensing

NDIR life

15 years

Weight

360g

Dimensions

130mm×90mm×40mm

Installment standard

65mm×65mm or 2”×4”wire box

Interface connections

Maxi. 9 terminals

Wiring standard

wire section area<1.5mm2

Approval Standard

CE-Approval

Programming and selection

Via internal jumpers and push-buttons on the panel

 

Features:

1) Non-dispersive Infrared Detector (NDIR) CO2 sensor with 15 years lifetime

2) Famous American Telaire CO2 sensor is inside and its detection range is up to 0 ~ 50,000ppm

3) ABC logic with patented self calibration algorithm makes users use it without
calibration

4) Real-time detecting and display of indoor CO2, temperature, and also humidity (option)

5) Providing 0~10V analog signal and relay dry-contact output

6) RS485 communication interface option makes the CO2 monitor can be connected with a remote PC

7) Optional on board relay with field adjustable trip point according to CO2, temperature or humidity (programmable selection)

8) CE approved

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer, Trading Company
Year Established
1999
Factory Size
Below 1,000 square meters
Total Employees
Fewer than 5 People

Recommended Categories

Explore top categories and find suppliers for your specific needs