Specifications
Real-time monitoring carbon dioxide (CO2) measurements during 0 to 20,000ppm rangeOptional real-time monitoring temp.,RH%
Wholesale co2 PPM controller
F2000IAQ-CO2 detector/Indicator is used to monitor and alarm CO2 level and room temperature. Relative humidity detection and display can be as an option. Other options can be provided to users: RS485 communication interface with independent address; one dry contact output to control a ventilation device.
Especial design for schools, kindergartens, office buildings, conference rooms, rest rooms as well as other public places
u Built-in NDIR CO2 module, 15 years long life.
u ABC Logic self calibration algorithm for CO2 sensor.
u Real-time detect and display room CO2 and temperature
u 3 LED indicator lights following three different CO2 ranges to indicate
ambiance ventilation situation: Optimal Ventilation; Poor Ventilation and Insufficient Ventilation.
u Optional humidity detection and display
Co2 PPM Controller Features
u Real-time detecting and display CO2 level during 0ppm to 20,000ppm CO2 range; Also detecting room temperature from 5 to 45°C
u Optional real-time humidity from 5%RH to 95%RH
u NDIR CO2 sensor technology of infrared self diffusion, 15 years lifetime
u Self Calibration Algorithm makes it in using without calibration amending
u The three measured CO2 ranges for 3-LED indicator lights selectable by end users
u LED’s brightness adjustment
u Optional 1X dry contact output or one 0~10VDC output to control a ventilation device
u Easy preset CO2 level for buzzer alert (optional)
u Optional RS485 interface to connect to a PC or another system (optional)
Specifications
Gas detected | Carbon Dioxide (CO2) |
Sensing element | Non-Depressive Infrared Detector (NDIR) |
Temperature sensor | NTC |
Temperature correction | Self compensation |
CO2 NDIR life | 15 years |
Consumption | 3.5W/ Max, 2.5W/ Average |
Accuracy@25°C(77°F) | ±40ppm + 3% of reading |
Stability | <2% of FS over life of sensor (15 yr typical) |
Warm up time | 2 hours (first time) 2 minutes (operation) |
CO2 measuring range | 0~2000ppm, which is default value 0~(1,000~20,000)ppm, programmable selection |
CO2 setting & Display resolution | 1ppm |
Temperature measuring range | 0~50°C(32~122°F) |
Temperature setting range | 5~45°C(41~113°F) |
Option: 1X dry contact output | Rated currency for contact point: 3A 220VAC/30VDC, resistance load |
Option: RS485 communication interface | 9600/14400/19200(default)/28800/38400bps rates selectable by program,15KV protection for static, independent address setting |
Operation condition | 0~50°C (32~122°), 0~95%RH without condensing |
Power supply | 220VAC/110VAC or 24VAC 50/60HZ±10% |
Weight | 380g |
Dimensions | 130mm×90mm×40mm |
Connections Interface | Locate in interface of connection |
Installment standard | 65mm×65mm or 2”×4” wire box |
Wiring standard | Wire section area<1.5mm2 |
Approval Standard | CE-Approval |
Programming and selection | DIP switches inside and external push-buttons |
Send Inquiry to This Supplier
You May Also Like
-
Telemecanique Sensors XSAV11801NegotiableMOQ: 1 Piece
-
Supply NOx Sensor Nitrogen Oxygen 12642311 12648631 12669595 12662972 12662971 For GMNegotiableMOQ: 1 Kilovolt
-
20428461 20732304 20428462 Heavy Duty Truck Sensor Parts Fuel Tank Level Sensor For VOLVONegotiableMOQ: 1
-
Liquid Level MeterUS$ 100 - 470MOQ: 5 Pieces
-
Balluff Inductive Sensor BES01TK BES Q08ZC-PSC20B-BP00,32-GS49NegotiableMOQ: 1 Piece
-
BALLUF Inductive Sensor BES M12MI-NSC40B-BV03 New Original StockNegotiableMOQ: 1 Piece
-
BALLUFF Sensor BESM18MI-PSC80B-S04G StructureNegotiableMOQ: 1 Piece
-
PY9060-Pressure Sensor With Display - IfmNegotiableMOQ: 1 Piece
-
S16200-Flow Monitor -lFMNegotiableMOQ: 1 Piece
-
Leuze HT3C/4P-M8 Diffuse Sensor With Background Suppression. Part No.: 50129375.NegotiableMOQ: 1 Piece