Features


u  Designed for real time measuring ambiance carbon

dioxide level, air quality (VOC’s), temperature and

relative humidity.

u  NDIR infrared CO2 sensor inside with special Self Calibration. It makes CO2 measurement more accurate and reliable.

u  More than 10 years lifetime of CO2 sensor.

u  Mix gases sensor with high sensitivity for

VOC and cigarette.

u  High accuracy temperature and relative  

humidity measurement optional

u  Combined both humidity and temperature

sensors seamlessly with digital auto

compensation

u  Provide up to 2 or 3 analog outputs for CO2, air quality (VOC’s) and temperature or relative humidity.

u  With LCD or without LCD selectable

u  LCD display CO2, temperature and humidity measurements as well as air quality (VOC’s) level.

u  Wall mounting type with easy installation.

u  Modbus RS485 interface with outputs for

CO2, temperature, humidity and air quality (VOC’s).

u  24VAC/VDC power supply or

u  EU standard


 

n  Detection Focus

ü  Carbon Dioxide (CO2)

Indoor CO2 level is a universal accepted parameter for the    

condition of indoor ventilation and air quality.

l  Non-dispersive infrared (NDIR) CO2 sensor with more than 10-year lifetime

l  ABC self-calibration technology guarantees reliable CO2 measurement

l  CO2 range: 0~2000ppm/0~5000ppm optional

l  Rapid response, high stability and consistency

 

 

ü  Air Quality (VOC)

The air quality sensor is a mix gases sensor with high sensitivity for VOC (kinds of volatile pollutant gases) such as

ammonia, toluene, formaldehyde and cigarette smoke, alcohol, H2S, and carbon monoxide. So it is very suitable to detector the general indoor air quality in real time and long term. It responds quickly to any change of the concentration of such gases.

l  Semi-conduct mix gases sensor with 5~7 years life time

l  High sensitive to volatile gases like ammonia, toluene, formaldehyde, cigarette smoke, alcohol, H2S, etc.

l  Small volume, lower consumption

 

 Temperature and humidity

Combined digital temperature and humidity sensor with high accuracy and stability. It also has compensation to

CO2 and air quality which makes the measurements more accurate by minimizing environmental effects.

 

n  Application

u  Building ventilation systems

u  Industry ventilation systems

u  Airport, train station, shopping mall, office, classroom and other public places for air quality measurement and

indication

 Specifications

Monitoring parameters

CO2

Air Quality (VOC’s)

Temperature

Relative humidity

Sensing element

Non-Dispersive Infrared Detector (NDIR)

Semiconductor mix gases sensor

Digital combined temperature and humidity sensor

Measuring range

0~2000ppm(default)

0~5000ppm

(selectable in the order)

1~30ppm

0~50°C(default)

-20~60°C selectable

0~100%RH

Display Resolution

1ppm

5ppm

0.1°C

0.1%RH

Accuracy@25°C(77°F)

±30ppm + 3% of reading

±10%

±0.5°C

±3%RH

Life time

15 years (normal)

5~7 years

10 years

Calibration cycle

ABC Logic Self

Calibration

     ——

——

——

Response Time

<2 minutes for 90% change

<1 minute

(for 10ppm hydrogen,

30ppm ethanol)

<5 minute

(for a cigarette)

in 20m2 room

<10 seconds to reach 63%

Warm up time

72 hours (first time)

1 hour (operation)

Electrical Characteristics

Power supply

24VAC/VDC

Consumption

3.5 W max. ; 2.5 W avg.

Outputs

Up to three analog outputs

0~10VDC (default) or 4~20mA (selectable by jumpers)

0~ 5VDC (selected in placing order, cannot be changed)

Modbus interface

RS-485 with Modbus protocol, 19200bps rate, 15KV antistatic protection, independent base address.

 

 Models Selection

 

G01-IAQ-B X Y C –Z 0 1 – U 02/05 Tab

 

      X: LCD or no LCD

1- basis type without LCD

3- standard type with LCD (LCD displays real-time measurement of CO2+air quality+Temp.+RH)

Y: Power socket

0-    without a power socket

3-    with a power socket to connect a power adaptor

C: 24VAC/VDC power supply

Z: analog output

3-3Xanalog outputs for CO2+air quality +Temp.(default)/RH (selectable by jumpers)

2-2xanalog outputs for CO2+air quality

0-no analog output

U: default analog output type

A- 4~20mA

V- 0~10VDC (default)

V05- 0~5VDC

           02/05: CO2 range

02- 0~2000ppm

05- 0~5000ppm

Tab: temperature scaling

   T05- 0~50°C (default)

     T06- 0~60°C

     T26- -20°C~60°C

 

Accessory (selectable at placing the order)

921: back plate for wall mounting

     921+922: desktop bracket

Top CO2 VOC Transmitter for BAS 

 

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer, Trading Company
Year Established
1999
Factory Size
Below 1,000 square meters
Total Employees
Fewer than 5 People

Recommended Categories

Explore top categories and find suppliers for your specific needs