IAQ Monitor/alarm
Specifications
CO2 + VOC + temp.,%RH monitor/ alarmwall mounting or desktop
3-color backlit LCD
buzzer alarm
1 on/off output,touch button
IAQ monitor/alarm
IAQ monitor/alarm Features
Designfor real time detection indoor air quality
NDIR infrared CO2 sensor with special SelfCalibration makes the CO2 measurement more accurate and more reliable.
More than 10 years lifetime of CO2sensor
More than 5 years lifetime of Semi-conductor TVOC (mixgases) sensor
Digital compositive temperature and humidity sensor withmore than 10 years lifetime
Three-color (green/yellow/red) LCDbacklitindicatingoptimal/moderate/poor ventilation
Twoalarm ways: buzzer alarm and backlight
colours switch
Provideoptional 1xrelay output to control a ventilator
Thetouch button for easy operation
Excellent performance forIAQ detection and
monitoring in home andoffice
220VACor 24VAC/VDC power selectable; power adaptor available; desktop and wallmounting type available
EU standard and CE-approval
IAQ monitor/alarm Focus
Carbon Dioxide (CO2)
Indoor CO2level is a universal accepted parameter for the condition of indoor ventilationand air quality.
A time period can be preset from 1 to 24 hours, e.g. 5hours, then the monitor can display CO2 average level during thisperiod, which provides an objective and true data for the measurement of the airquality in a certain space.
Non-dispersive infrared (NDIR) CO2sensor withmore than 10-year lifetime
ABC self-calibration technology guarantees reliable CO2measurement
CO2 range: 0~2000ppm/0~5000ppm optional
Rapid response, high stability and consistency
Mix Gases (TVOC-Total Volatileorganic compound)
VOC emitted from building materials, decoration materialsand furniture, includes toluene, ammonia, H2S, formaldehyde and other harmfulgases. Its necessary to real time detect these harmful gases. But it’s costlyto use the professional instruments to detect each single gas. Also it’spossible to monitor for daily use. These gasesexit in air for a long time and their volatilization level are different indifferent temperature and humidity,thereliability of such detection by a professional instrument for a single gas isvery limited.
This multifunction IAQ monitor uses amix gas sensor.It has high sensitive to kindsof volatile pollutant gases (VOC) such as ammonia, toluene,formaldehyde and cigarette smoke, alcohol, H2S, and carbon monoxide. So it is very suitable tomonitor the general indoor air quality in real time and long term. The mixgases sensor responds quickly to any change of the concentration of such gases.Not only you may open windows for fresh air coming but also the monitor cancontrol a ventilator/air-cleaning devise based on the indication and alarm.
Built in the semi-conductor mix gases sensor
5~7 years life time
High sensitive to volatile gases like ammonia, toluene,formaldehyde, sensitive to cigarette smoke, alcohol, H2S, etc.
Small volume, lower consumption
Temperature and humidity
Switzerland digitaltemperature/humidity sensor built in with high accuracy and stability. It alsohas compensation to CO2 and TVOC which makes the measurements moreaccurate by minimizing environmental effects.
LCD Display
Application
New G01-CO2 –B5 monitor/alarmis used to monitoring room CO2 and VOC, as well as room temperatureand humidity. It detects and monitors indoor IAQ level. It provides one on/off outputto control a ventilator according with the CO2 or VOC measurement or accordingwith both of them.
It provides both buzzer alarm andthree colors backlit switching alarm.
Hotel, exhibition hall, hospital, shop, restaurant, airport, train station, theater and other public places
House, villa, office, meeting room, classroom and other rooms
All ventilation systems
n Specifications
Monitoring parameters |
CO2 |
TVOC |
Temperature |
Relative humidity |
Sensing element |
Non-Dispersive Infrared Detector (NDIR) |
Semiconductor mix gases sensor |
Digital combined temperature and humidity sensor |
|
Measuring range |
0~5000ppm |
0~30ppm |
-20~60°C |
0~100%RH |
Display Resolution |
1ppm |
5ppm |
0.1°C |
0.1%RH |
Accuracy@25°C(77°F) |
±50ppm + 3% of reading |
±10% |
±0.5°C |
±4.5%RH |
Life time |
15 years (normal) |
5~7 years |
10 years |
|
Send Inquiry to This Supplier
You May Also Like
-
SICK ICR845-2E1020 SICK Industrial Barcode Scanner for Logistics & AutomationNegotiableMOQ: 1 Piece
-
ISX15 QSX15 Diesel Engine Pressure Temperature Sensor 4921475NegotiableMOQ: 1 Ampere
-
Pressure SensorNegotiableMOQ: 2000 Pieces
-
Sick WSE4S-3P3130H Order Number: 1052888 Product Family: W4S-3 Inox Hygiene Product Family: Photoelectric SensorsUS$ 100 - 200MOQ: 1 Piece
-
20428461 20732304 20428462 Heavy Duty Truck Sensor Parts Fuel Tank Level Sensor For VOLVONegotiableMOQ: 1
-
King Pigeon Temperature Humidity Transducer THI100 Temperature Humidity Detector Wireless SensorUS$ 2 - 31MOQ: 5 Pieces
-
Ultrasonic Position Liquid Level Position SensorUS$ 200 - 700MOQ: 1 Piece
-
Crank Oil Seal for Toyota Auto Parts Oem 90311-95012US$ 1 - 10MOQ: 1 Piece
-
SHT10 Humidity & Temperature SensorUS$ 1 - 2MOQ: 5 Pieces
-
Wholesales & Retails HCA131A High Performance Dual Axes Tilt Sensor Switch Led Light With Tilt Switch From Shenzhen FactoryNegotiableMOQ: 1 Piece