Specifications
1. Monitoring and control room CO2 level,as well as temperature and humidity.2.CO2 Controller for agriculture application.
Agriculture CO2 Controller for Co2 Generator
1) Multiple control functions and high performance with low price
2) Application in all ventilation systems, or public places
3) Wall mounting type and duct type selectable
4) Built-in pump type for some special applications
5) LCD display detecting both CO2 level and temperature, also relative humidity (optional)
6) NDIR infrared CO2 sensor with special ABC_Logic Self Calibration System and 15 years long lifetime. It makes the CO2 measurement more accurate and more reliable.
7) Specially provide the altitude calibration
8) Microprocessor control, quick response, high precision
9) Providing strong control outputs with up to three 0~10V analog outputs and three relay dry-contact outputs
10) The analog output with two alternatives: PID control output or linearized over full range output
11) Different control mode for delays selected by users applications such as ventilation systems or greenhouses
12) Locale adjustable range of CO2: 0~2,000ppm/0~5,000ppm/20,000ppm/ 0~50,000ppm;
adjustable range of temperature: 5~45adjustable range of humidity595%RH
13) RS-485 communication interface optional, 15KV antistatic protection, independent base address setting
14) Specially provide a simple CO2 controller with 6 indicator lights and a relay output to control a fan
15) CE-Approval
Gas detected | Carbon Dioxide (CO2) |
Sensing element | Non-Dispersive Infrared Detector (NDIR) with more than 10 years lifetime |
Temperature sensor | NTC |
Humidity sensor | HS series capacitive sensor |
Temperature dependence | 0.2% FS/°C |
Temperature correction | Self compensation |
Power supply | 100VAC~240VAC or 24VAC, 50/60HZ±10%, selectable in order |
Consumption | 3.5 W max. ; 2.5 W avg. |
Accuracy@25°C(77°F) | ±40ppm + 3% of reading (0~5,000ppm) ±75ppm or 10% reading whichever is greater (0~20,000ppm) |
Stability | <2% of FS over life of sensor (15 yr typical) |
Calibration interval | ABC Logic Self Calibration Algorithm |
Non linearity | <1% of FS |
Pressure dependence | 0.13% of reading per mm Hg |
Altitude calibration | Programmable from 0-9,900m in 100m increments |
Response Time | <2 minutes for 90% step change |
Signal update | Every 2 seconds |
Warm up time | 24 hours (first time) 10 minutes (operation) |
CO2 measuring range | 0~5,000ppm 0~20,000ppm (optional) |
CO2 setting & Display resolution | 1ppm |
Temperature measuring range | -20~60°C(-4~140°F) |
Temperature setting range | 5~45°C(41~113°F) |
Humidity measuring range | 0~99%RH |
Humidity setting range | 5~95%RH |
Output resolution | 10Bit |
Relay output | Three ways dry contact outputs with programmable selection to control CO2,temperature,humidity Rated switching current: 2A(220VAC/30VDC), resistance load |
Communication interface | RS-485, 9600/14400/19200(default)/28800 or 38400bps (programmable selection), 15KV antistatic protection, 3 independent base address, max network node 64. |
Flow rates | 80 ~ 120 cc/min |
Operation conditions | 0~50°C(32~122°F); 0~95%RH, non condensing |
Storage conditions | 0~50°C(32~122°F); 0~90%RH |
Weight | 360g |
Dimensions | 130mm×90mm×40mm |
Installment standard | 65mm×65mm or 2”×4”wire box |
Wiring standard | Wire section area<1.5mm2 |
Approval Standard | CE-Approval |
Send Inquiry to This Supplier
You May Also Like
-
Adjustable Wiggle Wires for Greenhouse Shade Cloth and Ventilation SystemsUS$ 10 - 50MOQ: 50 Bags
-
Specializing In The Production Thermal Sensitive Agriculture Sun Shade Net Cover Cloth For PlantNegotiableMOQ: 1 Piece
-
Venlo Glass GreenhouseUS$ 1 - 50MOQ: 500 Square Meters
-
Greenhouse Sun Shade Net,shade Net Price ,sunshade Net ClothUS$ 0.9 - 15MOQ: 100 Square Feet
-
Air Cargo Import ServiceNegotiableMOQ: 1 Set
-
Jeans DressNegotiableMOQ: 1 Set
-
Imperial Crown Key Chain PendantNegotiableMOQ: 1 Set
-
CD BagNegotiableMOQ: 1 Set
-
Consulting TableNegotiableMOQ: 1 Set
-
Agricultural Greenhouse Seedbed With Welded Wire MeshUS$ 2 - 12MOQ: 200 Square Meters