Home > Instruments & Meters > Lab Utensil and Disposable > Test Tube > KDC-1100III-X Isolator, Biohazard Safety Cabinet

KDC-1100III-X Isolator, Biohazard Safety Cabinet

KDC-1100III-X Isolator, Biohazard Safety Cabinet photo-1
Negotiable MOQ: 1 Piece (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Brand Name:
KINGDAK
Model Number:
KDC-1100III-X
Place of Origin:
Shanghai, China
Payment & Shipping
Payment Methods:
Port of Shipment:
SHANGHAI
Delivery Detail:
Delivery time depends on order quantity.
Brand Name KINGDAK
Model Number KDC-1100III-X
Place of Origin Shanghai, China

KDC-1100III-X Isolator, Biohazard Safety Cabinet

 

1. Complete sealed
Front window is sealed, and with pairs of gloves connecting to the operation area, product is transferred by the delivery window. And there is no out-connected valve.   

2. 100% exhaust
100% air exhaust, no air recirculation, and air is exhausted by three ULPA filters and to the room directly. If the air needs to be exhausted to outdoors, another out connected duct need to be ordered, and extra duct and motor are required.

3. Complete negative pressure
The two motors design makes interior of cabinet is complete negative pressure, and can reach -274PA, triple layers filter film, ensures operation's security, neither substance nor polluted air will leak out.

According to the performance criteria:
1 US Standard ANSI/NSF49: 2002
2 European Standard EN12469: 2000
3 Chinese Standard YY0569-2005

Certificates:   
ISO9001, ISO14001, ISO13485, CE

 

Technical parameter:

 

 

External Size
(W × D × H)
1100× 800× 1600 mm
Internal Size
(W × D × H)
750× 560× 600 mm
Pass Box Size Internal Size: 390× 380× 330 mm
 
Gloves One pair 800mm butyl rubber gloves
Material Work Surface: 304 stainless steel
Body: Expoxy coated cold-rolled steel
Air Velocity More than 355 cfm
Negative Work Zone   Pressure  
- 274 Pa
Pre-filter Washable
Main Filter Air supply filter: ULPA filter   99.999% efficient(0.1-0.3 microns)
First exhaust filter: ULPA filter 99.999% efficient(0.1-0.3 microns)
Second exhaust filter: ULPA filter 99.999% efficient(0.1-0.3 microns)
Noise ≤ 65 dB
Front Window Toughened glass, thickness is no less than 8 mm
Display LED
Alarm Visual and audio alarm
Lighting ≥ 800 lux
UV lamp UV lamp for sterilization
Power 110V~240V/50Hz~60Hz(Optional)
Accessories Gloves, fluorescent light, UV lamp, exhaust duct

 

 

 

KDC-1100III-X Isolator, Biohazard Safety CabinetKDC-1100III-X Isolator, Biohazard Safety CabinetKDC-1100III-X Isolator, Biohazard Safety Cabinet

 

KDC-1100III-X Isolator, Biohazard Safety CabinetKDC-1100III-X Isolator, Biohazard Safety CabinetKDC-1100III-X Isolator, Biohazard Safety CabinetKDC-1100III-X Isolator, Biohazard Safety Cabinet

KDC-1100III-X Isolator, Biohazard Safety CabinetKDC-1100III-X Isolator, Biohazard Safety Cabinet