Fetal Monitor (FM-600P)

Fetal Monitor (FM-600P) photo-1
Negotiable MOQ: 1 Set (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Type:
Ultrasonic Transducer
Place of Origin:
Guangdong, China
Model Number:
FM-600P
Payment & Shipping
Payment Methods:
Port of Shipment:
SHENZHEN
Delivery Detail:
Delivery time depends on order quantity.
Type Ultrasonic Transducer
Place of Origin Guangdong, China
Model Number FM-600P
Features:

Safe:Ultrasound dosage is under 50% of the safe standard.

Standard configure:FHR,  TOCO,  Fetal Movement

Optional:single or twins

Tone: Quality  "Sanyo" speaker take more clear and loud sound.

Display:12.1 high-resolution color TFT LCD display, support plug-in large-screen CRT display;Rotable Screen,Can be Viewed from different direction

Patent:  Special fetus awaking function within FHR probe.

Save function: Dynamic save and display the Monitoring information within 48 hours

Operation: Linux operation system,stable,easy to operate.

Auto-monitoring: Automatic monitoring mode,parameters can be preset

Power: Built-in rechargable Li-ion Battery, AC-DC Power supply,without interruption  monitor

Protable:Small size, convenient for multi bed monitoring and outside diagnosing.

Network :Support the extension almost for 128 units central monitor system

Specification:

FHR

Ultrasound Probe:12pcs chip, Multi-wafer,wavebeam,high sensitive

Frequency:1MHz ±5%

Intensity: <3mW/sq.cm

FHR range: 30-240bpm

Resolution:1bpm

Accuracy:1bpm/± 1%

TOCO

TOCO range:0-100 (relative unit)

Resolution:1

Non-linear error:  5%

Fetal Movement: Button Hand Count( Automatic cumulative number of movements)

NIBP

Measurement: Units:mmHg/Kpa optional

Pressure:  A double security protection software and hardware

protection:A double security protection software and hardware

Work Mode:Auto,Manual

Measurement: 2-60 minutes set up

Survey: Systolic blood pressure:60-240 mmHg ; Average Blood Pressure:40-200 mmHg ; Diastolic Blood Pressure: 30-180mmHg

Resolution:1mmHg

Accuracy:3mmHg

Pulse rate:40-240bpm

SPO2

Range:70%-99%

Resolution:1%

Accuracy: 2 Effective digital

Pulse Rate:40-240bpm

RESP

Range: 40-240bpm

Range:30-300bpm

Accuracy:1bpm/ 1%

Choice:I II III aVR aVL aVF V

Scan Speed:12.5mm/s 25mm/s 50mm/s

Gain choice:x0.25 x0.5 x1 x2

Application:Diagnosis,Monitor,Surgery

RESP

Range:1-99rpm

Resolution:1rpm

Accuracy:2rpm

TEMP

Range: 26 - 45

Resolution: 0.1

Accuracy: 0.2%

Working enviroment

Relative: temperature: 5- 40

Atmospheric: pressure:(86-106)Kpa,32 - 45 ±0.1)

Printer: 50mm usual thermal paper,more economical

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer, Trading Company
Year Established
2002
Factory Size
Below 1,000 square meters
Total Employees
Above 1000 People