Brief Introduction about IPLSystem
IPL (Intense Pulsed Light) is a kind of light with high energy and broad wavelength, within the range from 530nm to 1200nm. Photothermic and photochemical action will be triggered by the radiation of IPL. On one hand, IPL will promote collagen reproducing and recombining which makes the skin more flexible and smooth. On the other hand, the light with long wavelength can easily pass through epidermis layer and will be absorbed selectively in priority by pathological pigments which will be destroyed by high heat, and get the effect of remove pigmentations, vascular lesions and unwanted hair.
Technique Specification
Light source type:IPL xenon lamp
Light Energy: 15-50J/cm2
Pulse Amount: 1-6
Pulse width: 0.1ms-30 ms
Pulse delay: 0.1ms-100ms
Cooling: internal circulating water + cooling + wind cooling + semiconductor cooling
Safety protection: Impedance test
Spot Size : 8×40mm2
N.W.: 25kg
Dimension: 430mm×470mm×460mm
Voltage: 230V±10%, 50~60Hz
Standard Treatment Process
2.1 Form filling
Fill in the blanks of the Client File, confirm the treatment program, and remind the client pay attention to some points before and after treatment.
2.2 Face cleaning
Clean the face with gentle face cream for 3 minutes.
Remind: clean the hands of operator and the handpiece with
bromogeramine.
2.3 Preheating
Start the equipment after face cleaning; preheat for not less than 3
minutes (without lighting the xenon lamp).
2.4 Shaving
Standard Treatment Process
2.1 Form filling
Fill in the blanks of the Client File, confirm the treatment program, and remind the client pay attention to some points before and after treatment.
2.2 Face cleaning
Clean the face with gentle face cream for 3 minutes.
Remind: clean the hands of operator and the handpiece with
bromogeramine.
2.3 Preheating
Start the equipment after face cleaning; preheat for not less than 3
minutes (without lighting the xenon lamp).
2.4 Shaving
Shave the unwanted hair of the treatment area(2 minutes).
2.5 Gel coating
Coating the gel evenly (2-3mm) on the skin.
Effect:light guide, cooling, anaesthetisin.
Attention: no coating on eyes, eyebrows, lips.
2.6 Eye protection
Operator: wear the safety goggles.
Patient: close the eyes, wear professional safety goggles or cover the eyes with eye patch.
2.7 Allergic test
Emit 2 or 3 light spots in the bottom of ears in safe parameter, observe for 3 minutes.
Effect: do not continue to operate if there is an allergic phenomenon.
2.8 Operation
Carry on the operation with a suitable parameter to the patient.
Attention:
2.8.1 Inform the patient that there will be a slight pricking in operation before operating, to avoid panic.
2.8.2 Start the operation with a low energy grade; adjust the parameters in operating while asking the feeling of the patient.
2.8.3 Move the light spot by one spot overlapping the upper 1/3 part of the previous spot.
No emittng one area repeatedly, otherwise may cause inflaming or burns.
2.8.4 The handpiece should touch the skin vertically, no over pressing or leaving the skin.
2.8.5 Observing the reaction of skin while operating.
2.9 Cold compress
Keep gel coating for 20 minutes after operation ending; carry out cold compress in obvious slight reddish reaction till reddish fading away.
2.10 Cleaning
Clean the gel with cold water, coat corresponding cosmetics.
2.11 Treatment Course
Skin Rejuvenation Program: 30-45 days/time (4 times/course)
Hair Removal Program: 2-3months/time (3times/course)
2.12 Special reminding
2.12.1 Ask the client before treatment: is there a allergic or not; is there a bad reaction before for similar operation; fill the Client File concretely. Adjust the parameters on the basis of full acquaintanceconcretely. Adjust the parameters on the basis of full acquaintance of the condition of patient. Inform the patient the possiblereaction inoperation before operating.
2.12.2 In large area treatment or long time continuous operating, the water inside the equipment will warm up and the handpiece will be hot, interrupt the operation to refresh the water or leave the water cool down to continue operating.
2.12.3 Refresh the circulating water in one month; use purified water or medical distilled water.
welcome your enquiry
Send Inquiry to This Supplier
You May Also Like
-
ADM Alexandrite Laser for Face and Body 755nm 1064nm Alexandrite Laser Hair Removal Beauty Machine 755 Alexandrite LaserUS$ 3700 - 6500MOQ: 1 Piece
-
Skin Care Multifunction Beauty Machine Vertical E Light Ipl Qswitch Laser RF Face Lifting Machine With 4 HandlesUS$ 1 - 5000MOQ: 1 Set
-
Germany Bars!tria LaserUS$ 4,500 - 7,000MOQ: 1 Set
-
Wholesale Tria Beauty Tria Hair Removal LaserUS$ 5,000 - 6,500MOQ: 1 Set
-
0.1-2.6mm Scanning Fractional Co2 Laser Fractional Co2 Face Whitening Laser Beauty Equipment Fractional Co2 LaserUS$ 7,000 - 10,000MOQ: 1 Set
-
Newest Acne Treatment Hair Removal Tria LaserUS$ 1 - 10,000MOQ: 1 Set
-
Professional Wholesale Tria Laser Hair RemovalUS$ 1 - 5,000MOQ: 1 Unit
-
Elos Eplication Wholesale Tria Laser Hair RemovalUS$ 3,000 - 4,000MOQ: 1 Set
-
Discount Hair Removal, Tria 4x Laser Brand New Hair Removal, Tria Hair Removal Laser 4xUS$ 1 - 3,900MOQ: 1 Set
-
Hair Remover Laser Tria Hair Removal Laser With Great PriceUS$ 1 - 10,000MOQ: 1 Set