Beauty Equipment Manufacturer RF Carboxytherapy Fractional Ultra Pulse Co2 Laser FDA Approved
Technology of Ultrapulse
Mainly let the original average output of the laser energy concentrated in a very short period of time then output, due to the high pulse power, short time, and more round spot, the pressure on the surface from laser heat transfer effects is low (small heat-affected zone).
Beauty equipment manufacturer RF fractional ultra pulse co2 laser
CO2 fractional laser metal frame inside
CO2 fractional laser accessories
CO2 fractional laser principle
CO2 fractional laser effect principle is "focal photothermal effect ". Skin tissue has ability to repair itself. The skin was injury by trauma, but it could heal itself. The wound area is too large, the results of repair of scar formation. The wound is small, the skin can completely recover. Fractional laser every effect to skin only on one of the small region to generate thermal stimulation, retaining portion of skin is not affected, the role of tissue to the skin to stimulate collagen receipt hyperplasia, and no effect of skin tissue can be used as thermal diffusion region, avoid the possibility of thermal injury and other side effects, and can quickly promote skin healing, reach, and improve scars, skin firming pores purpose.

Treatment
Perfect skinwhiteningwrinkle removal acne preventionfacial beauty for human tissue burningvaporization and coagulation. Mainly used for local and facial skin, repair skin light aging, improve uneven skin, large pores, rough skin, the skin relaxation phenomena, especially applicable to dispel various scars and wrinkles, acne, tattoo, stains, and pigmentation, as well as on the surface of any part of a variety of moles, warts, acne, skin tag, treatment of hemangioma.
Color touch screen control panel
Technical parameters
| Laser wavelength | 10.6 μm ± 0.1μ M |
| Three output mode | Ultra pulse, continuous output and dot matrix output |
| The output terminal of power | 1~40W |
| Lattice point output energy of each | 5mj-100mj ( 16 speed adjustable ) |
| Fractional output total energy | 125mj+1kj |
| Scanner focal length | f=50mm ( FFLS ) or f=100mm ( HFLS ) |
| Focal spot diameter | ≤ 0.1mm≤ 0.2mm ( FFLS ), ( HFLS ) |
| Treatment of depth | 2000μ m ( FFLS ), 600 μ m ( HFLS ) |
| Guidelines for glory | Green semiconductor laser ( 532nm,≤ 5mW ) |
|
System control CO2 laser system The CO2 laser with a specific wavelength of 10.6 nm can be absorbed by human body tissue (no matter what color the skin is) by nearly 100%. Through laser emitter, the micropulsed laser beam shoots on the target skin in nanometer level to achieve a controllable precise treatment .The dimension of shooting area only can be measured in nanometer, which is precise enough for operators to control and adjust the treated depth andlayer according to the clinical diagnosis. The energy of CO2 laser is even and steady. Its focused energy aims only at target tissue without any injury to surroundings. It is the heat and electromagnetic effect of the laser that people use to conduct non-blood or less-blood cutting, cauterizing, gasification and accurate microsurgery so as to avoid skin burnt. During the treatment, biochemical reactions of optical-thermal accelerate collagen reproduction and skin recovery,after exfoliation of the tiny scar; fresh and smooth skin can be regenerated. The device outputs invisible laser. In order to operate with more ease, red semiconductor laser has been added to indicate. |
microcomputer control |
| Exhaust system | built-in smoke system |
|
Cooling system Application:
1. Application Range of Fractional treatment handpiece 2. Application Range of Incision Handpiece |
built-in closed water cooling circulation system |
| Display | interface ( 10.4 inch color touch screen ) |
| Light guide system | 2 joint torsion spring joint arm ( export) |
| Way of working | galvanometer scanning ( lattice ): |
| FFLS scan size | a maximum of 15*15mm |
| HFLS scan size | a maximum of 20*20mm |
| The oval, triangular (standard and adjustable ) | |
| Scan rate | >10m/s continuous: 1~30W, every step 1W adjustable; |
| Pulse frequency modulation Pulse frequency modulation | 0-999Hz, every step 1Hz adjustable |
| Environment temperature | 5~40 degree |
| Relative humidity | ≤ 80% |
| Power supply | 220V, 50Hz, 3A |
| Dimensions | 500mm 650mm 1100mm |
| Weight | 50kg |
| Scanning pattern | rectangle, square, triangle, circle, ellipse, straight line |
| Pulse interval | 0-5000ms, every step 1ms adjustable |
| LCD | 8/10.4 |
Curative effect contrast
Theory - co2 fractional laser
Send Inquiry to This Supplier
You May Also Like
-
Permanent and Painfree Facial Skin Resurfacing Machine IPL Beauty MachineUS$ 1 - 10,000MOQ: 1 Set
-
Home Use Facial Skin Resurfacing Mesotherapy Gun Beauty EquipmentUS$ 1 - 2,300MOQ: 1 Set
-
30W Medical Surgical Gynecology Fractional Co2 Laser System Cutting Facial Skin Resurfacing Surgery Beauty MachineNegotiableMOQ: 1
-
Hot Sales Laser CO2 Treatment Vaginal Tighten Machine Skin Resurfacing Facial Acne Scar Removal Co2 Fractional Laser MachineUS$ 1350 - 2500MOQ: 1 Piece
-
Vertical Ipl Machine Facial Resurfacing Skin RejuvenationUS$ 1 - 5,000MOQ: 1 Set
-
CO2 Laser Fraccionado Rejuvenecimiento Facial Laser Skin ResurfacingUS$ 1 - 10,000MOQ: 1 Unit
-
New-tech 3 in 1 Skin Renewing Facial ResurfacingUS$ 1 - 10,000MOQ: 1 Set
-
Fractional RF Micro Needle for Facial Wrinkle Removal and Skin ResurfacingUS$ 1,000 - 2,000MOQ: 1 Unit
-
New Style Portable Facial Resurfacing for Scar Removal Skin Tightening and WhiteningNegotiableMOQ: 1 Piece
-
Facial Skin Care Massager With Digital Display MH-GS01NegotiableMOQ: 500 Pieces