Vascular Lesions Removal Elight Ipl,fda Approved Laser Hair Removal Machine,shr Hair Removal Opt Laser
Vascular lesions removal elight ipl,fda approved laser hair removal machine,shr hair removal opt laser
permanent hair removal opt laser:
Applications of permanent opt laser:
Remove unwanted hair from any part of the body.
Removal or reduction of age spots, visible blood vessels, diffuse redness and uneven pigmentation while improving skin texture.
Removal or reduction of facila thread viens.
4.Acne Clearance
Reduction of inflammatory acne when used in combination with a topical cream or gel.
Removal or reduction of port wine stains, thread veins and other vascular lesions.
Removal or reduction of freckles, age spots and other pigmented lesions.
Technical parameter of opt laser:
Wavelength |
430nm/530nm/560nm/590nm/640nm-1200nm |
Handpiece number |
2 piece,one shr handpiece,one sr handpiece |
Cooling system |
semiconductor+air+water+cooling gel |
IPL light energy |
1-50(j/cm²) |
Pulse duration |
1-10ms |
Pulse NO. |
1-6 |
SHR pulse duration |
1-7ms |
SHR frequency |
1-10HZ |
SHR energy |
1-50J/CM2 |
Skin cooling |
-4°c-10°c |
Display |
10.4″color touch screen |
Output power |
2000W |
Voltage |
110v,50hz or 220v,60hz |
Wavelength |
Treatment of opt laser |
430-1200nm |
Acne removal |
480-1200nm |
Age spots, sun spots & pigmentation removal, skin rejuvenation |
530-1200nm |
Freckles removal, Skin rejuvenation |
560-1200nm |
Whitening skin, Skin rejuvenation |
580-1200nm |
Vascular removal, fade melasma, skin rejuvenation |
640-1200nm |
Thick Hair removal |
690-1200nm |
Soft Hair removal |
Hair removal of shr machine:
1. Cut or shave hair to 1-2mm or ask patients to shave at home 2-3 days before treatment.
2. Clear treatment area.
3. Turn on machine,
1). Use SHR, adjust pulse width at 7ms, frequency 5HZ, energy 10J/cm2.
2). Use normal hair removal treatment, put the 640nm or 690nm filter into the slot, select
"hair removal",adjust the parameter, set it to ‘ready’ .
4. Put cooling gel on treatment area about 2mm.
5. Wear protect goggles for patient and operator.
6. Shot the treatment area, let the crystal tip to touch cooling gel, You are permitted to have
1/3 overlapping on treatment area.
7. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area until heat disappear.
Skin rejuvenation:
1. Clear treatment area.
2. Turn on machine ,put the 560nm filter into the slot, select "skin rejuvenation",adjust the
parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.
Pigmentation Therapy:
1. Clear treatment area.
2. Turn on machine ,put the 480nm or 530nm filter into the slot, select "pigmentation
therapy",adjust the parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.
Vascular Therapy:
1. Clear treatment area.
2. Turn on machine ,put the 580nm filter into the slot, select "vascular therapy",adjust the
parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.
Acne Therapy:
1. Clear treatment area.
2. Turn on machine ,put the 430nm filter into the slot, select "acne therapy",adjust the
parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.
Wrinkle removal:
1. Clear treatment area.
2. Turn on machine ,put the 580nm filter into the slot, select "wrinkle removal",adjust the
parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.
Send Inquiry to This Supplier
You May Also Like
-
CE With Alexandrite Long Pulse Nd Yag 755nm 1064nm Painless Laser Hair RemovalUS$ 2000 - 3000MOQ: 1 Set
-
Profession Painless Laser Hair RemovalUS$ 1 - 2MOQ: 1 Set
-
Painless Laser Hair Removal Painless Fast Moving ElightNegotiableMOQ: 1 Set
-
Laser Depilator Painless Laser Hair Removal MachineUS$ 1,000 - 9,000MOQ: 1 Set
-
Totally Painless Laser Hair Removal sl 808/hair Removal Diode LaserUS$ 5,000 - 10,000MOQ: 1 Set
-
Professional OPT SHR IPL Painless Laser Hair Removal Machine Suitable For The Performance Of Skin CenterUS$ 1 - 3,000MOQ: 1 Piece
-
SUSLASER 808nm Diode Laser / Diode Laser AC220V/110V Hair Removal / Painless Laser Hair Removal WomenUS$ 1 - 9,000MOQ: 1 Set
-
Painless Laser Hair Removal Long PulseNegotiableMOQ: 1 Set
-
Permanent Painless Laser Hair Removal MachineNegotiableMOQ: 1 Set
-
Painless Laser Hair Removal With ODM/OEMUS$ 2,500 - 2,950MOQ: 1 Unit