Lingmei Hair Removal Ipl + E-light+ SHR 3 In Breast Lifting Up 1 Mini Hair Removal Device/home E-light Ipl Rf Wrinkle Removal
The range of IPL treatment:
(1)Everlasting hair removal:remove unwanted hairs under arms,on legs ,lips or other body part,etc.
(2)Pigmentation treatment:remove various kinds of pigment such as freckle,chloasma,aged spots,sunburn,etc.
(3)Telangiectasis treatment:treat angiotelec-tasis.
(4)Acne treatment:papule,tuber,Blain,acne,etc.
(5)Shrink pores,tighten skin,improve skin elasticity and glossiness.
(6)Eliminate and smooth wrinkles,acne treatment.
Lingmei hair removal Ipl + e-light+ SHR 3 in 1 Mini Hair removal device/home e-light ipl rf
permanent hair removal e-light ipl rf:
Applications of e-light ipl rf:
Remove unwanted hair from any part of the body.
Removal or reduction of age spots, visible blood vessels, diffuse redness and uneven pigmentation while improving skin texture.
Removal or reduction of facila thread viens.
4.Acne Clearance
Reduction of inflammatory acne when used in combination with a topical cream or gel.
Removal or reduction of port wine stains, thread veins and other vascular lesions.
Removal or reduction of freckles, age spots and other pigmented lesions.
Technical parameter of e-light ipl rf:
Wavelength | 430nm/530nm/560nm/590nm/640nm-1200nm |
Handpiece number | 2 piece,one shr handpiece,one sr handpiece |
Cooling system | semiconductor+air+water+cooling gel |
IPL light energy | 1-50(j/cm²) |
Pulse duration | 1-10ms |
Pulse NO. | 1-6 |
SHR pulse duration | 1-7ms |
SHR frequency | 1-10HZ |
SHR energy | 1-50J/CM2 |
Skin cooling | -4°c-10°c |
Display | 10.4″color touch screen |
Output power | 2000W |
Voltage | 110v,50hz or 220v,60hz |
Wavelength | Treatment of e-light ipl rf |
430-1200nm | Acne removal |
480-1200nm | Age spots, sun spots & pigmentation removal, skin rejuvenation |
530-1200nm | Freckles removal, Skin rejuvenation |
560-1200nm | Whitening skin, Skin rejuvenation |
580-1200nm | Vascular removal, fade melasma, skin rejuvenation |
640-1200nm | Thick Hair removal |
690-1200nm | Soft Hair removal |
Hair removal of e-light ipl rf:
1. Cut or shave hair to 1-2mm or ask patients to shave at home 2-3 days before treatment.
2. Clear treatment area.
3. Turn on machine,
1). Use SHR, adjust pulse width at 7ms, frequency 5HZ, energy 10J/cm2.
2). Use normal hair removal treatment, put the 640nm or 690nm filter into the slot, select
"hair removal",adjust the parameter, set it to ‘ready’ .
4. Put cooling gel on treatment area about 2mm.
5. Wear protect goggles for patient and operator.
6. Shot the treatment area, let the crystal tip to touch cooling gel, You are permitted to have
1/3 overlapping on treatment area.
7. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area until heat disappear.
Skin rejuvenation
1. Clear treatment area.
2. Turn on machine ,put the 560nm filter into the slot, select "skin rejuvenation",adjust the
parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.
Pigmentation Therapy
1. Clear treatment area.
2. Turn on machine ,put the 480nm or 530nm filter into the slot, select "pigmentation
therapy",adjust the parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.
Vascular Therapy
1. Clear treatment area.
2. Turn on machine ,put the 580nm filter into the slot, select "vascular therapy",adjust the
parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.
Acne Therapy
1. Clear treatment area.
2. Turn on machine ,put the 430nm filter into the slot, select "acne therapy",adjust the
parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.
Wrinkle removal
1. Clear treatment area.
2. Turn on machine ,put the 580nm filter into the slot, select "wrinkle removal",adjust the
parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.
Treatment theory
e-light beauty equipment CE beauty machine combines three advanced technologies:Bipolar Radio Frequency + IPL + Skin Contact Cooling
The working theory is heating the dermis to a target temperature gradually,at that target temperature, it damages the hair follicles and prevents re-growth effectively,meanwhile avoiding injury to the surrunding tissue.A high repetition rate of single pulses are delivered deep into the dermis,achieving high average power and therappeutically effectively heat bulit-up,without the risk of injury and no pain virtually.
Send Inquiry to This Supplier
You May Also Like
-
Budget-Friendly Laser Hair Removal Equipment for Personal At-Home Hair Removal SolutionsUS$ 2000MOQ: 1 Combo
-
A110 Home Laser Hair Removal IPLNegotiableMOQ: 1
-
Super Hair Removal OPT IPL MachineUS$ 2,500 - 4,000MOQ: 1 Set
-
808nm Ipl Hair Removal Home Hair RemovalUS$ 1 - 5,500MOQ: 1 Set
-
Home Ipl Hair Removal SystemUS$ 2,550 - 2,800MOQ: 1 Unit
-
Mini Ipl Home Hair RemovalUS$ 1 - 400MOQ: 1 Set
-
Home Ipl Hair Removal EquipmentUS$ 1 - 1,800MOQ: 1 Piece
-
Ipl Home Hair Removal LaserUS$ 1 - 5,500MOQ: 1 Unit
-
Super Discount!! Ipl Hair Removal,ipl Hair Removal Home for WholesalesUS$ 1 - 3,500MOQ: 1 Set
-
Mutifunctional Acne Removal Hair Removal Ipl Laser Hair Removal HomeUS$ 1 - 5,000MOQ: 1 Set