40w Professional Vaginal Tightening Vaginal Rejuvenation Ultra Pulse Professional Scar Removal Fractional Co2 Laser Equipment Wrinkle Removal
Fuctions and treatment effect of elight ipl rf
1.Permanent hair removal.
2.Smooth wrinkles, face-lifting
3.Deep flecks, epidermis flecks or pigment treating the telangiectasis
4.Promote collagen to grow, strengthen flexibility of skin
5.Acne treatment
6.Shrink the thick pore
7.For endogenous pigment: nevus of Ota, coffee spot, age pigment, freckle etc removal
8.For exogenous pigment: tattoo, eyeliner and eyebrow removal
9.Skin whitening
10.Striae gravidarum removal
Application:
1. Application Range of Fractional treatment handpiece
a. Large pores, Fine lines, Skin tightening and whitening, Skin loosen(Deep Wrinkles), Stretch marks.
b. Various Scars: Burn Scars, Acne Scars, Surgical Scars and Keloid;
c. Reconstruction of photoaging skin.
2. Application Range of Incision Handpiece
a. Via multiple handles it can be adapted to Gynecology, ENT, Neurology and general surgery
b. In cosmetic surgery, it can be adapted to incisions for Blephaplasty, Skin Tags and Ingrow Nails, Compound Nevus and Intra Dermal Nevus etc
Product name:Professional vaginal tightening,vaginal rejuvenation,scar removal fractional co2 laser equipment
Principle of fractional co2 laser equipment:
Vaginal tightening laser is the use of water uptake 10600nm gold standard laser,using a three-dimensional lattice technology and 360-degree circular emission perfect combination of technology, to produce 50-70 degrees Celsius in a controlled depth of the vaginal mucosa, stimulate lamina propria and myometrium newborn fibroblasts, and damaged collagen fibers, elastic fibers, such as restructuring, so as to achieve vaginal wall thickening and tighteningof the vagina so that firmness, sensitivity enhancement, vagina tight as ever.
Vaginal tightening laser does not produce skin burns due to high temperature, each capable of Homogeneous heat, acting on a few hundred nanometers thickness Mucosa organization.
It concerntrated trearmal heating of the vaginal tissue inner layers induces collagen and elastine contraction and regeneration of these proteins in the longer term. These molecular signal activate the entire wound healling process of the body's local immune system. The treatment outcome is the complete remodeling of the vaginal tissue in addition to re-establishment of firm “young like" vaginal tissue embedded with string-like, thick and long collagen fibers.

Application of fractional co2 laser equipment:
thermal radiation make Mucosa tissue contraction and collagen fibers thereby improving and restructuring vaginal tightening.
1. Shrink vagina: rapid tightening, constriction, lasting firmness.
2. Beautify vagina: dilute pigment, pink labia.
3. Moist vagina: increase secretion, eliminate dryness.
4. Maintenance vagina: deep rejuvenation, prevent aging.
5. To improve sensitivity.
6. Private health, balance PH, improve the internal environment.
Product Structure of fractional co2 laser equipment:
1. joints of seven light guide arm
by seven joint light guide arm to complete the laser beam transmission.
The light guide arm is the role of the laser transmission to patients to operation site (target).
2. scanner
Graphics scanner can scan output, rectangular, round, hexagonal, triangular and
other graphics, the largest area of about 20 * 20mm2 scanning;
3. Main unit
It includes a high voltage power supply, a low-voltage power supply, control
system, cooling system, laser system and blowing system.
4. Touch display panel
Mainly used for parameter setting
5.key switch
Akey into the key switch, go to the "open" position, the instrument power on, go
to the "off” position to cut the power, turn off the instrument.

6. wheels
7. Affusion hole
8. Overflow hole
9. Drainage hole
10. the power input socket
11. Foot switch
Treatment heads:
Advantage:
1. Unparalleled char-free ablation, vaporization, excision,
or incision of soft tissues
2. Reduced thermal damage to surrounding tissues
3. Rapid healing and minimal downtime
4. Stimulate deeper collagen with high pulse energy
5. LCD display panel provides easy operation with the latest
microprocessor technology
6. Adjustable scanning patterns and size
7. Adjustable intensity of pilot beam from zero to maximum
8. Adjustable pulse duration
9. Last treatment setting memorization
10. Automatic alarm system for operation and troubles
11. Covers all functions of conventional system
12. No consumable costs.
Technical parameter of fractional co2 laser equipment:
| Function allocation | Vagina Tightening Laser/ Fractional Laser/ Surgical cut laser |
| Display | 8.4 inches touch screen |
| Wavelength | 10600nm |
| System & Probes | 3 systems, 5 probes |
| Light power | 40w |
| Output | Single point, Continuous, super pulse, dot matrix |
| CPG Scanning | Yes |
| CPG scan motor | America (Chinese) |
| Cutting head(50mm/100mm) | 2+4 |
|
Vagina Tightening Laser protective jacket CO2 laser system The CO2 laser with a specific wavelength of 10.6 nm can be absorbed by human body tissue (no matter what color the skin is) by nearly 100%. Through laser emitter, the micropulsed laser beam shoots on the target skin in nanometer level to achieve a controllable precise treatment .The dimension of shooting area only can be measured in nanometer, which is precise enough for operators to control and adjust the treated depth andlayer according to the clinical diagnosis. The energy of CO2 laser is even and steady. Its focused energy aims only at target tissue without any injury to surroundings. It is the heat and electromagnetic effect of the laser that people use to conduct non-blood or less-blood cutting, cauterizing, gasification and accurate microsurgery so as to avoid skin burnt. During the treatment, biochemical reactions of optical-thermal accelerate collagen reproduction and skin recovery,after exfoliation of the tiny scar; fresh and smooth skin can be regenerated. The device outputs invisible laser. In order to operate with more ease, red semiconductor laser has been added to indicate. |
Titanium alloy protective jacket*2 |
| Cooling Method | Air + Water Cooling |
| Dot distance | 0.1-2.6mm (adjustable) |
| Pulses energy | 0.1-180mj (adjustable) |
| Focal spot diameter | 100um-2000um |
| Output figure | Square,Triangle, Hexagon, Circle, Oval, Rectangle |
| Focal spot quantity | 1(1*1)-40000(200*200)(adjustable) |
| Figure square | 0.1mm*0.1mm-20mm*20mm(adjustable) |
| The way of luminous | 360 angle pyramidal reflex and 45 angle Slant reflex |
| Scanning mode | in order, disorder, midsplit |
| Operation Panel | 8.4 inches colorful touch screen |
| OSD Language | Chinese, English |
| Working voltage | AC:220V+ 10%, 50Hz; 110V+ 10%, 50Hz |
| Net Weight | 45kgs |
| Gross Weight | 60kgs |
Main Technical Parameters:
Laser wavelength: 10.6µm
Laser unit:TEM00 module Co2 unit (best quality for the facula)
Output power: super pulse output 0.3-7W, peak value 450W,continuous output 0.3-25W
Laser output mode: continuous, single pulse, repeat pulse, super pulse, with the optional pixel laser handpiece for Pixel laser output mode
Treatment theory
e-light beauty equipment CE beauty machine combines three advanced technologies:Bipolar Radio Frequency + IPL + Skin Contact Cooling
The working theory is heating the dermis to a target temperature gradually,at that target temperature, it damages the hair follicles and prevents re-growth effectively,meanwhile avoiding injury to the surrunding tissue.A high repetition rate of single pulses are delivered deep into the dermis,achieving high average power and therappeutically effectively heat bulit-up,without the risk of injury and no pain virtually.
Conducting system: seven joints longer articulated arm(the most advanced conducting light system in the world and the only one in China). It could be operated in the scope of R=1.7m, which makes the operation more flexible
Handpiece:multiple function handpiece and two kinds of focus lens for f=100mm and f=50mm. With the optional adapter, it could be used for orthopedic, gynaecology and ENT surgery
Operation mode:controlled by a touch screen and with the engineer interface and the doctor interface
Min. spot diameter:≤0.1mm, variable spot adjusting handpiece:0.1-2.5mm
Pulse width: the minimum pulse width is 0.1ms
The range of IPL treatment:
(1)Everlasting hair removal:remove unwanted hairs under arms,on legs ,lips or other body part,etc.
(2)Pigmentation treatment:remove various kinds of pigment such as freckle,chloasma,aged spots,sunburn,etc.
(3)Telangiectasis treatment:treat angiotelec-tasis.
(4)Acne treatment:papule,tuber,Blain,acne,etc.
(5)Shrink pores,tighten skin,improve skin elasticity and glossiness.
(6)Eliminate and smooth wrinkles,acne treatment.
Send Inquiry to This Supplier
You May Also Like
-
Sun Damage Recovery Co2 Laser Machine Factory Spot Scar Vagina Cleaning Pigment Removal Sale Beauty Machine Fractional Co2 Laser CarboxytherapyUS$ 6,500 - 9,000MOQ: 1 Piece
-
Acne Scar Laser TreatmentUS$ 1 - 6,000MOQ: 1 Unit
-
Co2 Laser Treatment for Pitted Acne ScarsUS$ 1 - 10,000MOQ: 1 Unit
-
Acne Scar Treatment Co2 Laser FrationalUS$ 6,000 - 13,000MOQ: 1 Set
-
Hot Sales Laser CO2 Treatment Vaginal Tighten Machine Skin Resurfacing Facial Acne Scar Removal Co2 Fractional Laser MachineUS$ 1350 - 2500MOQ: 1 Piece
-
Dermaroller Treatment for Acne ScarsUS$ 15 - 20MOQ: 20 Units
-
High Quality Beauty Machine Scar Removal Acne Scar Laser TreatmentUS$ 1 - 10,000MOQ: 1 Set
-
Wholesale Products Acne Scar TreatmentNegotiableMOQ: 1 Piece
-
Resurfacing Acne Scar Removal TreatmentUS$ 1 - 5,000MOQ: 1 Set
-
Hot Selling Pigment Therapy Acne Treatment Acne Scars Co2 Fractional LaserUS$ 1 - 10,000MOQ: 1 Set







