Home > Health & Medicine > Beauty Equipment > Skin Beauty Equipment > Co2 Fractional Laser For Diode Laser Birth Mark Removal 808nm Hair Removal Equipment Skin Renewing

Co2 Fractional Laser For Diode Laser Birth Mark Removal 808nm Hair Removal Equipment Skin Renewing

Co2 Fractional Laser For Diode Laser Birth Mark Removal 808nm Hair Removal Equipment Skin Renewing photo-1
US$ 10,000 - 15,000 MOQ: 1 Piece
Key Specifications
Get Latest Price
Laser Type:
CO2 Laser
Q-Switch:
Yes
Style:
Stationary
Payment & Shipping
Payment Methods:
Port of Shipment:
Beijing
Delivery Detail:
Delivery time depends on order quantity.
Laser Type CO2 Laser
Q-Switch Yes
Style Stationary
Certification CE
Place of Origin Beijing, China
Brand Name Goldenlaser
Model Number GL016
Feature Blood Vessels Removal, Face Lift, Pigment Removal, Skin Tightening, Skin Rejuvenation, Wrinkle Remover, Acne Treatment

 Theory - co2 fractional laser

    CO2 Fractional laser is the most advanced conceptual fractional CO2 skin peeling laser system with a wavelength of 10600nm. In addition to its fine skin-peeling effect, it can effectively penetrate the laser beam into the dermis . It is the most beneficial skin recovery system and can achieve the long-term effect of collagen remodeling as well as improvement of aged skin conditions due to exposure to light. It can be very safely applied to various types of scars compared to the existing 100% total layer skin peeling lasers (CO2 or Er: YAG). In addition, it does not require a long period of recovery or side effects. It can remodel various types of deformed scars and skin tissue very effectively.


Specifications


2 fractional laser

  co2 fractional laser for co2 fractional laser for diode laser 808nm hair removal equipment

1.Product parameters:

Application:

 

1. Application Range of Fractional treatment handpiece
    a. Large pores, Fine lines, Skin tightening and whitening, Skin loosen(Deep Wrinkles), Stretch marks.
    b. Various Scars: Burn Scars, Acne Scars, Surgical Scars and Keloid;
    c. Reconstruction of photoaging skin.

2. Application Range of Incision Handpiece
    a. Via multiple handles it can be adapted to Gynecology, ENT, Neurology and general surgery
    b. In cosmetic surgery, it can be adapted to incisions for Blephaplasty, Skin Tags and Ingrow Nails, Compound Nevus and Intra Dermal Nevus etc


CO2 laser system

The CO2 laser with a specific wavelength of 10.6 nm can be absorbed by human body tissue (no matter what color the skin is) by nearly 100%. Through laser emitter, the micropulsed laser beam shoots on the target skin in nanometer level to achieve a controllable precise treatment .The dimension of shooting area only can be measured in nanometer, which is precise enough for operators to control and adjust the treated depth andlayer according to the clinical diagnosis.

The energy of CO2 laser is even and steady. Its focused energy aims only at target tissue without any injury to surroundings. It is the heat and electromagnetic effect of the laser that people use to conduct non-blood or less-blood cutting, cauterizing, gasification and accurate microsurgery so as to avoid skin burnt. During the treatment, biochemical reactions of optical-thermal accelerate collagen reproduction and skin recovery,after exfoliation of the tiny scar; fresh and smooth skin can be regenerated. The device outputs invisible laser. In order to operate with more ease, red semiconductor laser has been added to indicate.


Laser Type  

 co2 fractional laser

Wavelength

  10600nm

Beam Delivery   

  7-joint arm

Maximum Output Power

 35W/25W/15W (optional)

Optical Beam Quality   

TEM

Spot Size  

 0.12-1.25mm (Adjustable)

Power of the Aiming Beam 

<5mW

Aiming Beam  635nm

 635nm

Scanning Mode 

 Randomized Scanning

Laser Operating Mode l

 UltraPulse, CW, Fractiona

Cooling  

 Air Cooling

Pulse Energy 

 10mj~200mj (every stepping:2mj)

Spot Pattern  

Triangle/Square/Rectangle/Rhombus

Pulse Interval 

 1ms~100ms (every stepping:1mj)

Scan Area  

10mmx10mm,20mmx20mm,30mmx30mm

Working Mode 

Continuous operation

Spot Density  

 

36 spots/cm² , 144 spots/cm², 576spots/cm² with intermittent loading

Power Supply  

AC 220V 50Hz/AC 110V 60Hz

Gross Weight 

88KGS

Dimensions(before packaged) 

650mmx340mmx760mm

Dimensions (after packaged) 

760mmx455mmx975mm

2.Treatment Theory

Fractional laser light penetrates the skin with tiny thermal channels through the random scanning, creating an ablative and thermal effecton only channels (a micro-injury) without damaging the surrounding tissue. The tissue surrounding the micro-injury sites (about 15-20% of the treatment area) starts the process of healing. As collagen remodels, skin tightened, scars improved and pigmented lesions removed.

 

3.Application

(1). Application Range of Fractional treatment handpiece

a. Large pores, Fine lines, Skin tightening and whitening, Skin loosen(Deep Wrinkles), Stretch marks.

b. Various Scars: Burn Scars, Acne Scars, Surgical Scars and Keloid;

c. Reconstruction of photoaging skin.

(2). Application Range of Incision Handpiece

a. Via multiple handles it can be adapted to Gynecology, ENT, Neurology and general surgery

b. In cosmetic surgery, it can be adapted to incisions for Blephaplasty, Skin Tags and Ingrow Nails, Compound Nevus and Intra Dermal Nevus etc

 

4.GLO16 Advantages

(1)Three modes of laser energy output are selective: UltraPulse, CW and Fractional modes

(2)Adopt COHERENT RF-excited laser system enables the output quality more stable, more uniform, more consistent, (compared to ordinary CO2 laser installed with glass tubes)

(3)lHealing zone volume is adjustable, namely the volume of spots is adjustable in a certain healing zone. Therapists could adjust the spot density upon skin type, lesion parts and effectiveness requirement of different patients

(4)l Various spot volumes are suitable for different area of the body which maximally avoid the side-effect that result from the overlap of the spot, reduce the pain during the treatment, satisfy different therapiests' unique request. 

(5)12.1"  TFT touch LCD, rotated 360° gives you a luxury enjoyment;

(6)Reserved entry access for laser room ensures a safe treatment

(7)Comparing with existing traditional CO2 Sealed Glass Laser, RF excited CO2 lasts nearly permanently, therefore it deserves a higher initial cost which will be offset by a much lower total of ownership.

Technology of Ultrapulse
Mainly let the original average output of the laser energy concentrated in a very short period of time then output, due to the high pulse power, short time, and more round spot, the pressure on the surface from laser heat transfer effects is low (small heat-affected zone).

Product Tags: carbon laser peel , laser removal of acne scars , skin tightening laser machine

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Gold Verified Supplier
6Yrs
Business Type
Manufacturer, Trading Company
Year Established
2010
Factory Size
Below 1,000 square meters
Total Employees
101 - 200 People

Recommended Categories

Explore top categories and find suppliers for your specific needs