Professional Medical Ce Beauty Equipment Fractional Co2 Laser Vagina Tightening For Pigment Removal &wrinkle &acne &scar Removal Wart Removal
CO2 laser system
The CO2 laser with a specific wavelength of 10.6 nm can be absorbed by human body tissue (no matter what color the skin is) by nearly 100%. Through laser emitter, the micropulsed laser beam shoots on the target skin in nanometer level to achieve a controllable precise treatment .The dimension of shooting area only can be measured in nanometer, which is precise enough for operators to control and adjust the treated depth andlayer according to the clinical diagnosis.
The energy of CO2 laser is even and steady. Its focused energy aims only at target tissue without any injury to surroundings. It is the heat and electromagnetic effect of the laser that people use to conduct non-blood or less-blood cutting, cauterizing, gasification and accurate microsurgery so as to avoid skin burnt. During the treatment, biochemical reactions of optical-thermal accelerate collagen reproduction and skin recovery,after exfoliation of the tiny scar; fresh and smooth skin can be regenerated. The device outputs invisible laser. In order to operate with more ease, red semiconductor laser has been added to indicate.
professional medical ce beauty equipment fractional co2 laser for pigment removal &wrinkle &acne &scar removal
1.CE,1 year warranty
2.RF,glass tube
3.15w/25w/30w/35w
4.Coherent/Access tube
Applications of professional medical ce beauty equipment fractional co2 laser for pigment removal &wrinkle &acne &scar removal
1. Skin renewing and resurfacing
2. Smooth burnt scars and surgery scars, etc
3. Wrinkle removal, skin tightening
4. Acne and acne scar removal
5. Remove intractable chloasmas and pigmentation
6. Sun damage recovery
Features of professional medical ce beauty equipment fractional co2 laser for pigment removal &wrinkle &acne &scar removal
1. Particular designed intelligent laser control system ensures a precise treatment
2. Laser energy shooting is an even steady and safe treatment process.
3. Wide range application, effective treatment
4. Easy and fast treatment, no down time.
Main specifications:
Basic specification | |
Laser mode |
Low-valance mode |
Wavelength |
10.6μm, far-infrared laser |
Pulsed radiofrequency |
0.530 W |
Control |
Touching switch, microprocessor-controlled |
Display |
LCD display |
Lcd |
1.Max power : 120W 2.Pulse width: 0.05-1s |
Pulse |
1. Average power: 40W 2. Pulse frequency:33.3 Hz |
Working mode: |
Continuous, single pulse, repeat pulse and super plulse |
Scan Graphics |
Square, rectangle, round or customized graphics |
Dot quantity |
400 dots at most |
Working state |
Hyper-pulsed mode |
Scan mode |
Sequence scan or Random scan |
Pulse energy |
10mj to 130mj is optional for each dot. Application:
1. Application Range of Fractional treatment handpiece 2. Application Range of Incision Handpiece |
Technical specification | |
Laser apparatus |
Sealed off laser device stimulated by direct current |
Condenser focus |
f=100mm |
Beam divergence angle |
0.3 mrad |
Spot size |
Min 0.2mm at the focus |
Radiation time |
1 ms |
Interval time |
1 ms |
Aiming beam |
Less than 2mW, 635nm red semiconductor laser |
Cooling system |
Closed loop circulating water |
Environment temperature |
5-400C |
Relative humidity |
<80% |
Temperature in transit |
-40-500C |
Humidity in transit |
<85% |
Beam transport device |
Articulated arm with 7-joint and balance weight |
Atomospheric pressure |
86.0kkpa-106.0kpa |
Warning up time |
5 min |
Electromagnetic requirement |
No electromagnetic Field interference |
N. weight (kg) |
55kg |
Power supply |
230V/110V |
Main Technical Parameters:
Laser wavelength: 10.6µm
Laser unit:TEM00 module Co2 unit (best quality for the facula)
Output power: super pulse output 0.3-7W, peak value 450W,continuous output 0.3-25W
Laser output mode: continuous, single pulse, repeat pulse, super pulse, with the optional pixel laser handpiece for Pixel laser output mode
Conducting system: seven joints longer articulated arm(the most advanced conducting light system in the world and the only one in China). It could be operated in the scope of R=1.7m, which makes the operation more flexible
Handpiece:multiple function handpiece and two kinds of focus lens for f=100mm and f=50mm. With the optional adapter, it could be used for orthopedic, gynaecology and ENT surgery
Operation mode:controlled by a touch screen and with the engineer interface and the doctor interface
Min. spot diameter:≤0.1mm, variable spot adjusting handpiece:0.1-2.5mm
Pulse width: the minimum pulse width is 0.1ms
Send Inquiry to This Supplier
You May Also Like
-
Online Laser Marking Machine CO2 Laser Machine CO2 Laser Engraving MachineNegotiableMOQ: 1 Set
-
Fractional CO2 Laser Erbium CO2 Laser Skin Tightening Laser Machine Dermatology EquipmentUS$ 900.00 - 1000.00MOQ: 1 Set
-
Skin Care/ CO2 Fractional Laser Beauty 40w Machine/scar Remove Spot Scar Pigment RemovalUS$ 1 - 9,000MOQ: 1 Set
-
Fractional CO2 Laser 10600nm for Professional Scar Removal & Skin ResurfacingUS$ 1100 - 1300MOQ: 1 Unit
-
GCA Series 30W Flying CO2 Laser Marking Machine for Date Batch Logo QR Code Barcode MarkingNegotiableMOQ: 1 Set
-
Co2 Fractional Laser for Veterinary Co2 LaserUS$ 10,000 - 15,000MOQ: 1 Piece
-
Co2 LaserUS$ 0.13 - 0.15MOQ: 50 Pieces
-
Co2 Laser Surgical / Co2 Surgical Laser MachineUS$ 1 - 9,888MOQ: 1 Set
-
Co2 Laser Beauty LaserUS$ 1 - 10,000MOQ: 1 Set
-
Maquina Laser Co2US$ 4,800 - 12,000MOQ: 1 Set