Hot New Products for 2015 Portable Digital Mobile Ecg Machine With SpO2/nibp/pulse Inspection
Hot new products for 2015 portable digital mobile ecg machine with SpO2/nibp/pulse inspection
PM-8000 integrates the functions of,ECG collection,SpO2,auscultation and PR inspection. The product is applicable for family, hospital, private Clinique, community medical treatment.etc.
Main Features
- Compact and portable, easy to use
- Display of ECG waveform, heart rate,SpO2 ,pulse rate ,pulse waveform
- Earphone output and 16 steps volume adjustable
- Alarm for SpO2 and pulse rate exceeding limits
- Real-time detecting, TF card data record and review
- Real-time clock
- Recorded data can be transferred to a PC
- PC analysis software
- Low power consumption
Technical specifications
Physical Characteristics
Size: 110(length)*60(wicth)*15(height)mm
Weight:100(including lithium battery)
Environment
Transport and storage
Temperature: -10℃~ +50℃
Relative Humidity: 10% ~ 95%
Atmospheric pressure: 50kPa ~ 106Kpa
Working environment
Temperature: 5℃~40℃
Relative Humidity: 20%~80%
Atmospheric pressure: 70kPa~106kPa
Batterytype: charging lithium battery
Working-viktageL: DC3.6V~DC4.2V
Power: ≤120mA
LCD display: 2.4"TFT, 320*240 Pixels
Continuous running time: 7hours
Main Parameters
(1) Measurement of auscultation volume
Heart sound range: 20Hz~230Hz
Lung sound range: 100Hz~800Hz
Heart lung combination sound range: 20Hz~800Hz
(2) Measurement of Heart Rate
Range: 30bpm~300bpm
Resolution: 1bpm
Accuracy: ±2bpm or ±2%(select larger)
(3) Measurement of SpO2
range: 0%~100%
resolution: 1%
accuracy: When the SpO2 measurement range is 70%~100%, the permission of absolute error is ±2%. Below 70% unspecified.
(4) Measurement of pulse rate
Range: 30bpm~250bpm
Resolution: 1bpm
Accuracy: ±2bpm or ±2%(select larger)
(5) Measurement Performance in Weak filling Condition
SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2%(select larger).
(6) Resistance to surrounding light
The deviation between the value measured in the condition of man-made light and indoor natural light and that of darkroom is less than ±1%
Packing&Shipping
All items are exported by standard wooden packing with alloy frame. Machine will be complete accommodating in it properly.

Choose Me
OEM:Yes
Experienced for many years:Yes
Exhibition Attended:Yes
Research&Develop Team:Yes
CE Certificate:Yes
Custom Personalized Service :Yes
High Quality:Of course!
Contact Us, More Surprise
Send Inquiry to This Supplier
You May Also Like
-
Medical Hospital Radiography Room Protection X-ray Lead Glass for SaleNegotiableMOQ: 1 Set
-
Digital ThermometerNegotiableMOQ: 5000 Pieces
-
Dengue IgG/IgM and NS1 Test CassetteNegotiableMOQ: 1
-
Hot Sale Cheap Cheap Portable Colorful Finger Pulse OximeterUS$ 1 - 35MOQ: 100 Pieces
-
Set of 80pcs pH Test Paper Strips Brand New and High QualityUS$ 1 - 100MOQ: 100 Pieces
-
729017 REFLEX HAMMER GIFTS SETNegotiableMOQ: 1000 Pieces
-
2017 Composition Analyze Equipment 9D NLS Sub-health Detector Best 9d Nls Diagnostic ScannerUS$ 480 - 700MOQ: 1 Set
-
Digital Thermometer Flexible TypeNegotiableMOQ: 5000 Boxes
-
Car Trunk Strip-for SealingUS$ 0.5 - 2.5MOQ: 1000 Meters
-
Temperature Indicator for Environmental Scan/5 Level/Irreversible/WaterproofUS$ 110 - 220MOQ: 40 Units





