The working principle of electro magnetic lock is that when power on the lock will generate electromagnetictism to absorb the mount plate to lock the door. It is fail safe maglock. Power on to lock and power off to unlock. Electromagnetic lock can be installed by two ways,hanging installation and flushing installation. electric magnetic locks are wildly used in offices, buildings exit doors, banks, financial institutions and other places. Maglock can be installed to wooden door, glass door, metal door and so on. According to the different doors, sometimes will need U brackets or L&Z brackets to support mounting. The whole system includes electric lock,power suply,access controller,exit button,door bell or RFID cards.
Bedroom door lock Technicals
| Product | 180KG(350LBS) single door electro magnetic lock |
| Lock Dimension | 205*36*23.5(mm) |
| Armature Plate Dimension | 130L*33W*9.3H(mm) |
| Holding Force | 180KG(350LBS) |
| Input Voltage | DC12V or DC24V |
| Current | 12V/320mA 24V/160mA |
| Suitable Humidity | 0-90%(non-condensing) |
| Cover Finish | Drawing oxidation |
| Lock Finish | Chrome plating |
| Armature Plate Finish | Chrome plating |
| Suitable | Wooden door,Glass door,Mental door,Sliding door. |
| Safety Type | Fail Safe |
| Weight | 1.9KG |
| Standard Packing | 10pcs |
| Dilivery | Prompt Delivery |
| Working Temperature | -30°C-55°C |
Bedroom door lock Features
| High Level EM Lock | Middle Level Lock | |||
| Item |
HLEM400series HLEM600series HLEM660series HLEM1100series |
MLEM400series MLEM600series MLEM660series MLEM1100series
|
||
| Material | ![]() |
Pure ironDT4C | ![]() |
Top grade silicon sheet |
| Coil | ![]() |
100%copper | ![]() |
60%copper 40%Aluminum |
| Finish | ![]() |
Top grade polished chrome | ![]() |
Zinc plating-bule white |
| Advantage | ITEM HLEM |
1.Design without Mechanical Failure 2.No residual magnetism 3.Adjustable mounting bracket 4.Life of more than five years 5.Pure iron is not easy deformation 6.The super rally adsorption force 7.Low heat 8.Lock body temperature of 20°C CE certificate
|
ITEM HLEM |
1.Strong tensile force,the suction force 2.Life of four years 3.Normal heat 4.Lock body temperature of 40°C
|
| Benefit | For Customer |
Quality no worries High-grade products Availble in high-end To get the trust of customers Future market trends |
For Customer |
Reliable quality the majority of current market for this type |
Troubles & Shootings
| Troubles | Cause | Shooting |
| Door can not lock |
1.circuit malfunction or low voltage 2.The power supply wire is too thin and long and to cause big decrease of voltage. 3.Power supply is broken to cause no voltage output. 4.The positive and negative wire of power supply is connectied in reverse. 5.The power supply is no power input |
1.Check the connection, and measure the voltage to see if it is normal 2.Modify or change the power supply wire to thicker one 3.Check the power polarity and correct the connection 4.Check to see if the power supply or controller is correctly connected to NC. Make sure to set up the controller |
| No transform of indicator output and low holding force |
1.The mount plate and electromagnetic lock face is not in complete close 2.The mount plate is fixed too tight, no room to move 3.The electromagnetic lock and plate are not at the same level or the door is deformed or moved 4.The surface of electro magnetic lock and mount plate is not clean 5.Power supply with low voltage 6.The power supply wire is too thin and long 7.The electromagnetic lock is malfunction |
1. Check the face of mount plate and magnetic lock, if the face of mount plate is deformed to cause no complete close to the lock. Please change the plate 2.Check the rubber gasket is put into the stick of plate, and adjust the bolt of plate not too tight at least a little movable 3.Adjust the surface of mount plate and electromagetic lock at the same lever and close completely. 4. Clean the surface of lock and plate. if rusted to affect its normal working, please change the part. 5.Use multimeter to check the voltage and current of electromagnetic lock to see if it is normal. or need repairing or changing power supply 6.Change into high quality power supply wire, better no more than 20 meters. 7.Repair or change the electromagnetic lock |
| Door can not open | The power is not cut off | To check out the connection of power supply and contoller. The electromagnetic lock is power on to lock and power off to unlock. The lock can be open once the power it is cut off. |



Payment:
If the total amount is less than 500USD, we prefer to accept Paypal or Western Union; For big amount we accept bank transfer.
Shipment:
Normally we will use UPS, DHL, FEDEX, TNT or EMS express. It usually takes 3-7 working days depending on the countries deliver to.
We can also arrange other shipment way per your requirement and instruction, such as sea shipment, air shipment, etc.
Warranty:
Warranty for one year, maintenance forever, change within 3 months because of product quality.
Send Inquiry to This Supplier
You May Also Like
-
Door LockNegotiableMOQ: 2700 Pieces
-
Outside Body Parts HJDL-188B Golden Dragon Mini Bus Parts Door Lock SystemNegotiableMOQ: 1 Piece
-
Kitchen Cabinet Cupboard Push To Open Touch Mini LatchNegotiableMOQ: 1 Piece
-
Hot Selling Best Quality Small Plastic Hook Security Lock Slatwall HooksUS$ 0.11 - 0.15MOQ: 1000 Pieces
-
Handle Lock With Strong Water Resistance SP-MS101-1NegotiableMOQ: 100 Pieces
-
Aluminium Door Lock MA300US$ 2 - 10MOQ: 500 Pieces
-
Office Door Security Door Lock and KeysUS$ 5 - 80MOQ: 2000 Pieces
-
Fashion High-end Self Locking LockUS$ 0.3 - 0.5MOQ: 5000 Pieces
-
Matt Surface Zinc Alloy Turn Sanp HookFor Handbag, Plated Turn Snap Hook BuckleUS$ 0.65 - 1MOQ: 2000 Pieces
-
TSA 3-dial Combination LockNegotiableMOQ: 1