Key Specifications
Get Latest Price
Place of Origin:
Germany
Brand Name:
Delphin
Model Number:
Log Message Series
Payment & Shipping
Payment Methods:
Port of Shipment:
Mumbai
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin Germany
Brand Name Delphin
Model Number Log Message Series

Specifications

Profi Signal Go software included in package
LAN interface for data transfer
Differential and galvanic isolation of inputs

data acquisition logger

BENEFITS:

  • Profi Signal Go software included in package
  • LAN interface for data transfer
  • Differential and galvanic isolation of inputs
  • Integrated signal conditioning
  • 1GB internal memory for 128 million data records
  • 2 configurable serial ports
  • Protocols: Modbus RTU and TCP, separate protocols
  • A range of internal calculation and logic channels
  • Monitoring and alarm functions
  • Drivers: OCX, OPC, LabVIEW, DASYLab,
  • Web Server interface

Various Applications:

  • Stand alone, universal data logging
  • Temperature measurement
  • Remote data transfer via GSM / UMTS
  • Tests and trials
  • Product testing and quality assurance
  • Process monitoring and alarm functions
  • Process data acquisition
  • Fault analysis with recorder functions
  • Laboratory data acquisition and management
  • GPS logging
  • Facility monitoring
  • Status and event logging
  • Energy consumption acquisition and measurement

Technical Specifications

CAL INFORMATION

LOG MESSAGE

Weight

1 kg

Dimensions

200 x 73 x 118 mm

Material

plastic enclosure

Humidity

80%, non-condensing

Temperature range

-20 .. 60°C

Supply

12 - 36 VDC VAC external

Power input

max. 10 W

Mounting

DIN rails or screw fixings

LAN interface

10 Base-T (half Duplex) / TCP/IP, UDP, ICMP

Data storage

Size

1 GB

Measurement values

up to 128 millions

Analog inputs

Resolution

24 bit

Current

0 .. 20 mA, 4 .. 20 mA

External shunt required

10Ω, 50Ω, 100Ω, 125Ω, 250Ω, 500Ω

Voltage

±156 mV, ±312,5 mV, ±625 mV, ±1,25 V, ±2,5 V, ±5 V, ±10 V

RTD as 2, 3, 4 wired

Pt50, Pt100, Pt250, Pt500, Pt1000, Pt5000

Thermistor

YSI400

Thermocouple

Types K,E,N,L,J,S,U,R,T,B,C

Resistance measurement

0 .. 10 k

Galvanic isolation

750 VDC to system and supply
400 VAC between channels for LogM 500

Withstanding voltage

110 VDC max

Input resistance

> 1 G(10 MLogM 500)

Precision

Thermocouples

0,1 % from measurement range to compensation

V / mA

0,01 % from measurement range

Pt100 / Pt1000

0,1 K / 0,01 K

Analog outputs

Current

0 .. 20 mA, 4 .. 20 mA

External shunt

max. 700

Resolution

16 bit

Precision

0,05 %

Galvanic isolation

750 VDC to system and supply

Digital input

 

TTL low level

0 .. 1,5 V @ 0 .. 1,5 mA

TTL high level

3 .. 90 V @ 2 mA

Refresh rate

1 kHz

Galvanic isolation

2,5 kV between channels

Digital inputs (counters)

TTL low level

0 .. 1,5 V @ 0 .. 1,5 mA

TTL high level

0 .. 1,5 V @ 0 .. 1,5 mA

Frequency

max. 30 kHz

Counter

16 bit (0 .. 65535)

Gate time

16 bit (0 .. 65535)

Precision

 

Range 0 .. 1 kHz

1 Hz

Range 1 .. 10 kHz

5 Hz

Range 10 .. 30 kHz

10 Hz

Digital outputs

Switching voltage

50 VDC max

Switching current