Adult/infant Pulse Oximeter With Bluetooth

Adult/infant Pulse Oximeter With Bluetooth photo-1
Negotiable MOQ: 100 Pieces (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Type:
Blood Testing Equipments
Brand Name:
Longfian
Place of Origin:
Hebei, China
Payment & Shipping
Payment Methods:
Port of Shipment:
Beijing
Delivery Detail:
Delivery time depends on order quantity.
Type Blood Testing Equipments
Brand Name Longfian
Place of Origin Hebei, China
Model Number JAX-205, JAX-205

Specifications

The appearrance of small,design for children
Suitable for observation in a variety of light
With pulse sound,alarm function

JAX-205(LED display)
Adult/infant pulse oximeter with bluetooth
The appearrance of small,design for children
Suitable for observation in a variety of light
With pulse sound,alarm function
Automatic power-off when no finger detected
Technical specifications
Measurement of SpO2
Measuring range: 0%100
Accuracy: When the SpO2 measuring range is 70%100,the permission of absolute error is ±2Below 70% unspecified
Measurement of pulse rate
Measuring range:30bpm250bpm
Accuracy: ±2 bpm or ±2% (select larger)
Resolution
SpO2 : 1%,  Pulse rate: 1bpm.
Measurement Performance in Weak Filling Condition
SpO2and pulse rate can be shown correctly when pulse-filling ratio is 0.4%.SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to surrounding light
Thedeviation between the value measured in the condition of man-made lightor indoor natural light and that of darkroom is less than ±1%.
Power supply requirement: : 3.6 V DC ~ 4.2V DC.

1.Smart appearance,more suitable for children
2.Two-colour screen,the display direction can be changed
3.Possess pulse sound and alarm function
4.Can display bar-graph and waveform.
5.Low power indication
6.Power-off automatically when no finger detected

JAX-205(LCD display)

Adult/infant pulse oximeter with bluetooth
Technical specifications
Measurement of SpO2
Measuring range: 0%100
Accuracy: When the SpO2 measuring range is 70%100,the permission of absolute error is ±2Below 70% unspecified
Measurement of pulse rate
Measuring range:30bpm250bpm
Accuracy: ±2 bpm or ±2% (select larger)
Resolution
SpO2:1%,Pulse rate:1bpm.
Measurement Performance in Weak Filling Condition
SpO2and pulse rate can be shown correctly when pulse-filling ratio is 0.4%.SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to surrounding light
Thedeviation between the value measured in the condition of man-made lightor indoor natural light and that of darkroom is less than ±1%.
Power supply requirement: : 3.6 V DC ~ 4.2V DC.