Specifications
1.We are the manufacture2.We can make the OEM service is customer requested
Advantage :
l Automatically control,constant pressure water supply
l One pump one varaible frequency controller,easy operation
l No need control panel to save cost,low faulty
l Automatically restart running after recover of power-off or low water level
l No need storing tank to save occupied area of pump house and avoid secondary pollution for water quality
l The equipment runs well even without individual posts and property management of residence community
l PID control method to monitor water consuming conditions and entering into stop mode automatically if no water use
Detailed Product Description
Special Inverter designed for pump
One drives one
Both for single pump and Mult-Pump System
Power Range up to 350KW
This Series Power Range:
Single phase 220-240V 1HP-3HP(0.75KW-2.2KW)
Three phase 220-240V 1 HP-15HP(0.75KW-11KW)
Three phase 380-440V 1 HP-470HP(0.75KW-350KW)
Technology Features
Input & Output
Input Voltage Range: 380/220V± 15%
Input Frequency Range: 47~63Hz
Output Voltage Range: 0~rated input voltage
Output Frequency Range: 500Hz
I/O Features
Digital Switch Input: 3 input
Programmable Analog Input: AI1: 0~10V or 0~20mA input;
AI2: 0~10V or 0~20mA input
Relay Output: 2 Output
Function Characteristics
Multi-Pump Control: Can realize 1 master and Max. 5 auxiliaries combine work
Sleep Function: Sleep down when have no water consumption, to earn a better energy saving
Freeze-Proofing Function: Suitable to low temperature area, prevent pump from freezing
Anti-clogging Function: Take precaution against pipe clogging and clean the pipe dirt
Power On Restart: Running automatically when power on
Master Fault Shift Automatically: Keep on working when the master break down
Alternate Running: Balance every pump's running time, prolong service life of the whole unit machine
Day-Part Function: 3 independent day-part control, up to 7 day-part achieved when define separated
Two Running Mode: Synchronous control mode, master-slave control mode
Terminal Control Mode: Terminal Run/Stop, Manual/Auto Control, Electronic Contact Gauge Control
Various of water supply Fault Alarm Function: High-Pressure, Low-Pressure, Low-Level, Transducer Error etc.
As many as 22 kinds of fault protection function: Over-Current, Over-Voltage, Low-Voltage, Phase-Failure, Over-Load etc
Send Inquiry to This Supplier
You May Also Like
-
Custom Compact 1000kVA 20kv Oil Immersed TransformerNegotiableMOQ: 50 Sets
-
ABB DSTDN020 3BSE003238R1NegotiableMOQ: 1 Piece
-
WOODWARD 8901-457 – Industrial Control Module for Engine/Turbine Protection and Speed ManagementNegotiableMOQ: 1 Bag
-
Motorola MVME167-34B VME Bus Single-board ComputerNegotiableMOQ: 1 Piece
-
11kv 33kv Oil Immersed Power Transformer Distribution TransformerNegotiableMOQ: 50 Sets
-
Factory Direct Sales, Can Be Customized 35kv-250kVA Oil-Immersed Power TransformerNegotiableMOQ: 50 Sets
-
UL Clip on Clamp T16 100A 0.333V Cts Split Core Current TransformerNegotiableMOQ: 50 Sets
-
220kv Power Transformers 100mva Oil Immersed TransformerNegotiableMOQ: 50 Sets
-
Low Loss High Voltage 11kv/100kVA/50kv/500kv Withstand Voltage Oil Immersed Test TransformerNegotiableMOQ: 50 Sets
-
Power Transformer Epoxy Resin Cast Dry-Type Transformer Distribution Electrical Transmission Transformer With 11kv 50kVANegotiableMOQ: 50 Sets