Home > Instruments & Meters > Test Instrument > Test Machine > Professional and High Detection Accuracy Coating Thickness Measuring Gauge

Professional and High Detection Accuracy Coating Thickness Measuring Gauge

Professional and High Detection Accuracy Coating Thickness Measuring Gauge photo-1
Professional and High Detection Accuracy Coating Thickness Measuring Gauge photo-2
Professional and High Detection Accuracy Coating Thickness Measuring Gauge photo-3
Professional and High Detection Accuracy Coating Thickness Measuring Gauge photo-4
Professional and High Detection Accuracy Coating Thickness Measuring Gauge photo-5
Professional and High Detection Accuracy Coating Thickness Measuring Gauge photo-6
Negotiable MOQ: 1 Set (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Place of Origin:
China
Brand Name:
PULANI
Model Number:
2013PLN-YT
Payment & Shipping
Payment Methods:
Port of Shipment:
Ningbo/Shanghai
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin China
Brand Name PULANI
Model Number 2013PLN-YT
Power Electronic
Usage Other, Measure coating thickness on metal substrate
Product Description

 

Professional and high detection accuracy coating thickness measuring gaugeProfessional and high detection accuracy coating thickness measuring gaugeProfessional and high detection accuracy coating thickness measuring gaugeProfessional and high detection accuracy coating thickness measuring gaugeProfessional and high detection accuracy coating thickness measuring gauge

Professional and high detection accuracy coating thickness measuring gaugeProfessional and high detection accuracy coating thickness measuring gaugeProfessional and high detection accuracy coating thickness measuring gauge 

Product Function

Professional and high detection accuracy coating thickness measuring gauge

Basic instructions:

1 . Automatic shutdown time: 30s
2.There are 4 kinds of state mode : measurement status, Statistics status, view data
status , calibration status.
A) Measurement status: display of measured values.
B)View data status :20 sets of historical data through.
C) Statistics status: maximum, minimum, average value.
D) Multi-point Calibration status :
F) Auto Calibration status : calibration measurements, and the gauge has 6 kinds of
calibration mode of 0.0 um, 50um, 100 um,250um ,500 um.

Key function instructions
 K1 (+) function :
A :Short press K1 (+), When you in different status, it will show you different function as
below :
1) In the measurement status,short press “+”, the unit will be switch from um to mil .
2) In the view data status,short press “+”, it can turn up to show the data .
3)In the statistics status of “MAX” ,short press “+”,the background light will be off .
4)In the calibration status, short press”+”,it can switch 6 kinds of calibration mode of 0.0 um,
50um, 100 um,250um ,500 um in turn.
B: long press K1(+), When you in different status, it will show you different function as
below :
1)In the measurement status, long press “+”, it will enter to the multi-point calibration mode
2)In the view data status, long press “+”, delete a single data selected
3)In the statistics status of “MAX”, long press “+” , it could be light on /off the background
light, but if the screen is black one ,you can not see the data.
4)In the auto calibration status: exit the calibration status to the measuring status
 K2 (MENU)function
A: short press K2(menu),When you in different status, it will show you different function as
below :
1)In the Non-calibration status: measurement status, view data status and statistics status
be switched in turn.
2)In the both of auto and multi-point calibration status: exit the calibration status to the view
data status
B: long press K2(menu),When you in different status, it will show you different function as
below :
1)In the auto measurement status: enter the auto calibration status
3)In the statistics status and View data status: invalid
K3 (-)function
A: short press K3 (-)
1)View data status: turn down to show the data
2)Statistics status: invalid
3)The calibration status: switch 6 kinds of calibration mode of 0.0 um, 50um, 100
um,250um ,500 um in turn .
B: long pressK3 (-):
1)In the Measurement status: restore factory (it will removal of historical data and the
calibration parameters) .
2)In the View data status: clear the historical data (including 20 measurements, the
maximum, minimum and average), the calibration parameters keep constant.
3)In the Statistics status: invalid
4)In the calibration status: exit the calibration status to the measuring status

Packaging & Shipping


5 pcs gauges you received are with sample package. Now there are 2 types of regular package:

(1) 1 complete set of gauge package: 1 pcs gauge, 1 set calibration, 1 instruction, 1 black glasses box.

Professional and high detection accuracy coating thickness measuring gauge

 

 

 (2) 5 complete sets of gauge package: 5 pcs gauge, 5 sets calibration, 5 instructions, 5 black glasses boxes, 1 white carton box whose outside is with the color cover.

 Professional and high detection accuracy coating thickness measuring gauge

 

  

Company Information

Professional and high detection accuracy coating thickness measuring gaugeProfessional and high detection accuracy coating thickness measuring gaugeProfessional and high detection accuracy coating thickness measuring gauge 

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Trading Company
Year Established
2012
Factory Size
Below 1,000 square meters
Total Employees
51 - 100 People

Recommended Categories

Explore top categories and find suppliers for your specific needs