Home > Products > Closed Cooling Tower > Weight Of Cooling Towers
Weight Of Cooling Towers
- 600 Set / Sets per Month
- qingdao
- T/T Credit Card
Product Details
Condition: | New | Cooling Type: | Counter Flow | Material: | Metal |
Place of Origin: | Shandong, China | Brand Name: | Heng An Closed Cooling Tower | Model Number: | Closed cooling tower |
Voltage: | As Model Closed Type Water Cooling Tower | Power(W): | 110-415v etc | Dimension(L*W*H): | As Model Closed Type Water Cooling Tower |
Weight: | As Model Industrial Closed Circuit Water Cooling Tower | Certification: | ISO9001 | Warranty: | 12 month |
After-sales Service Provided: | Overseas service center available |
Product Description
Weight Of Cooling Towers
The closed circuit cooling tower advantage experience
Application in engineering
1.Water-source heat pumps
2.Self-contained cooling units
3.Chilers
4.Free cooling applications
5.Date centers
6.Hybrid evaporative/dry cooling
7.Cooling special fluids
8.Compressor jacket cooling Inter cooling,Aftercooling
9.Machine jacket cooling
10.Induction furnaces
11.Consolidating multiple loads into a single cooling nuit
The closed circuit cooling tower advantage
1.VS.Cooling Tower +Heat Exanger Combination
Closer approach to wet bulb temperature and reduce fouling improve process efficiency
2.VS.Air-Cooled Systems
10-20°C lower process temperatures ,less required space ,and lower energy consumption .
3.VS.Once –Through Systems
Reduces environmental impact ,saving up to 95% of the cooling water .
4.Reduced installed Cost And Space Requirements
Effectively combines the function of a cooling tower and heat exchanger into one piece of equipment ,reduce required piping and system complexity .
Technical parameters
Cooling Tower Total circulating water | 1800m3/h |
Cooling Tower Inlet water temperature | 43°C/33°C |
Cooling Tower Out water temperature | 35°C/25°C |
Wet-bulb temperature | 22°C/16°C |
System Design pressure | 0.2MPa |
Drift circulating water loss | 0.01% |
Cooling tower air intake | sides(inlet side of the barrier-free) |
Process principle of Mixed flow series
Structure and main parts
1.Propeller Fan
2.Spray pump
3.Imported board of Zinc-plate and Aluminum-plate
4.Condensing Coils
5.Electronic Water-Curing Device
6.Set Up Dehydrator
7.Advantage Water Distribution System
8.PVC Wet Deck
Engineering considerations
1.Location
Closed Circuit Cooling Towers must have an adequate supply of fresh air to all inlets.
When units are located adjacent to building walls or in enclosure .Care must be taken to ensure that the warm ,saturated discharge air is not deflected and drawn back to the air inlets .
2.Think on compatibility of liquid (gas)
The fluid to be cooled must be compatible with the coil material .Fluids not compatible with ciol materials can lead to corrosion and tube failure .Certain fluids may require occasional pressure cleaning or mechanical cleaning of the inside of coil tubes .in such cases the coil must be designed to provide this capability .
3.Piping and Valves
Piping must be size and installed in accordance with good piping practice .All piping should be supported by pipe hangers or other supports ,not by the cooling tower .External shut off valves may also be required if the system design necessitates the isolation of individual tower cells .
4.Capacity Control
In general season ,the performance of most closed circuit cooling tower will vary dues to the change of its environmental wet bulb temperature .Therefore ,when the change of environmental temperature leads to the difference of liquid temperature ,in this case ,capacity control will be required .
How to prevent the cooling towers to be freezed
1.Protection Against Basin Water Freezing
2.Protection Against Coil Freezing
Application Fields
1.Towers in Central Air Conditioning
2.Closed Circuit Cooling Towers in Heat Treatment Industry
3.Air Compressor Cooling System
4.Towers in Metallurgy Industry
5.Special Industry
Part of the product photos
Certification
FAQ
(1)Your company is a manufacture or trading company?
We are a leading cooling tower manufacturer for 38 years . It is“famous brand”-Heng An manufacture in China
(2) What is the difference between a "counter flow" and a "cross flow" cooling tower?
The crossflow or counterflow designation characterizes the orientation of the airflow within the heat-transfer media (fill) in the tower with respect to the direction of water flow.
In counterflow towers air travels vertically upwards through the fill and makes intimate contact with water droplets falling down through the fill media. Hence the air and water travel in opposite directions.
In crossflow cooling towers the air passes through the fill media in a horizontal direction, thus crossing the downward water flow. Counterflow towers are inherently more efficient than crossflow towers.
(3) How do I get repair parts and how long does it take?
Complete Parts Workshop, and can supply all parts
90% of Spare parts can be distributed to any place on the world within one week!
Contact Us
- Weifang Heng An Import & Export Co., Ltd.
- Contact nameyan Li
- Phone86-536-6103201
- AddressRoom1210,No.4 Building Zuoanhuating No.2613,Yuhe Road Kuiwen District Weifang City Shandong Province Weifang,Shandong
- high quality Square cooling tower wholesale price
- Good price Industrial FRP Counterflow Round Cooling Tower Supplier
- Good Price FRP Cross Flow industry square cooling tower supplier
- low noise counterflow FRP Industrial round cooling tower for chiller
- Open Type Cross Flow Industrial FRP Square Water Cooling Tower
- Produced by Jinggang Factory Industrial and commercial central air conditioning cooling towers
- Produced by Jinggang Commercial central air conditioning cooling tower and Cooling tower for casting cooling
- Produced by Jinggang Commercial central air conditioning cooling tower and DN1400 ammonia synthesis tower
- Produced by Jinggang Commercial central air conditioning cooling tower and Cooling tower for quenching production line cooling
- Produced by Jinggang Commercial central air conditioning cooling tower and Cooling tower for industrial furnace cooling
- Galvanized steel water tanks
- biochemical sponge filter
- Cooling Tower Spray Nozzle: LZ-9
- Vinyl Seawall Panels: U type
- Good price cross flow pvc cooling tower fill pack packing sheet media
- Wholesale inventory PVC sheet cooling tower pvc filling medium
- Chinese suppliers S wave Design 500*1000mm Honeycomb Fill pack
- High quality natural draft cooling tower infill packs
- Fast delivery Cross-flow Cooling Tower Pack Fill Frp Cooling Tower Filter
- Hot sale Counter Flow Cooling Tower PVC Fills/Packing/Filler s wave cooling tower fill
- S-wave packing, oblique cross packing, step type trapezoidal oblique wave packing
- Natural draft cooling tower infill packs, PVC cooling tower fill
- pvc cooling tower fill pack packing sheet media cooling tower filling material for sale
- Black Counter Flow Cooling Tower PVC Fills/Packing/Filler s wave cooling tower fill
Popular Searches
Recommended Products
- Module 2711P-RDT12C 2711P-RP1 1764-MM2 Controller 1764-LRP Module 1746-OB16 AC Drive 22F-D8P7N103 22F-D2P5N103 20F11NC030JA0NNNNN
- 2711P-RP1 Module 2711P-RN15S Module Allen-Bradley 1784-PCMK PCMCIA 5069-IF8 5069 Module 5069-IB16 5069 5069-OW16 5069 5069-L306ER Controller 1756-IA32 Input Module 1764-MM2 1764-28BXB
- Soft Starters 150-C201NBD SMC-3 20F1ANC205JN0NNNNN Frequency Converter 2711P-T10C4A7 PanelView 1606-XLE80E 2198-D032-ERS4 2198-S130-ERS3 Kinetix 5700 Single Axis Inverter 2711P-K4M5D8
- The price of river garbage cleaning boats
- Low Price PVC PP PE Plastic and Wood Profile for Window and Door Profile Production Line plastic profile making machine
- Hitachi DC variable frequency scroll compressor GK2A150DGA-XA1S cold storage air conditioning
- Hitachi DC frequency conversion LS400DHD-64DBG professional air conditioning compressor
- GJR2390200R1411 Central Control Module GJR2391500R1210 1SVR730712R1400 1SFA664003R1060 1SFA664003R1150 1SFA664003R1100 SFA664001R1001 3BHE024577R0101 3BDH000021R1
- Control Systems 3BSE020520R1 CI810B 3BSE008510R1 DO810 ACS355-03E-31A0-4 ABB Control Module ACS355-03E-12A5-4 AF400-30 SDCS-REB-2 3BDZ000398R1 3HNE01586-1 DSQC377
- 31LF-00500 Switch XKAH-00017 Gear-Input 81Q5-40130 Speed Sensor R140W-9 R210W-9 ZGAQ-01270 Gear Ring Condensor 11EM-90050 4JJ1 Hyundai water Pump 8980476883 Pusher XKAY-00056 Throttle Control Unit 4631128 Shaft 39WQ8-41170 Relief Valve 4446002 R210-5 Wate
- Cylinder head valve cover
- Cylinder head flange
Find Similar Products By Category
- Machinery > Refrigeration & Heat Exchange Equipment > Cooling Tower
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
yan Li
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-