Shenzhen Factory Supply Emergency Li-ion Type Ups Battery 24v 50ah AAA Grade 18650 Batteries for Solar Power System
Model: |
DEL-UPS3 |
|
PV/Solar pannel PV |
voltage |
18V |
powder |
20W |
|
PWM solar controller: |
voltage |
12V |
current |
3A |
|
PV maximum voltage |
25V |
|
BATTERY |
Type of battery |
AAA lithium polymer 18650 battery |
QTY and Capacity of batteries |
12V/100A 24V/50A |
|
Charge current |
0.35A |
|
Discharge current |
2A |
|
Float voltage |
13.5-13.8Vdc |
|
DC system |
USB: |
2pcs*5V/2A |
DC output |
4 outlets of 12V/1.5A |
|
AC system |
Rated power |
150W |
voltage |
115V/230VAc(1±5%) |
|
Wave form |
Modified Sine Wave |
|
frequency |
50/60Hz |
|
No-load current |
<0.3A |
|
characteristics of charge and discharge |
Charging time |
5-7Hour |
Time of duration |
18-20Hour(5W LED light) |
|
PHYSICAL | ||
Unit dimension(mm) |
195*200*320mm |
|
Net weight(Kg): |
6 |
|
ENVIRONMENT |
Indoor or outdoor with water proof Temperature 0℃~40℃,Humidity |
|
Environment of performance: |
20%~90%,noncondensate |
|
Noise level |
|
less than 40dB |
Note:the models of suffix with A are without AC system. | ||
1. Wide range of input voltage
The UPS can offer normal and stable service voltage under its input voltage range. When the input voltage is out of its range the machine will switch to battery mode automatically to keep the output power in order to protect the equipment, such as computers, ensure they will not be damaged by the over high or over low voltage, users can continue the operation of equipment for a while or save the data on computers while the power network is abnormal.
2. Wide range of AVR(Automatic voltage regulation)
In the product’s input voltage range and under 3 steps of intelligent AVR function, it can provide a stable output voltage.
3. Automatic self detection when UPS on(LED).
Before the UPS on, red, yellow, blue LED will light up two times by cycle turns, after self detection UPS switch to AC mode/battery mode or working mode.
4. Silence function
In the "battery mode", shortly press the switch to turn off the buzzer. But the battery is about to run out or the load is too heavy, the buzzer sound cannot be muted.
5. Overload protection
In the battery mode, output voltage turn down correspondingly when it is overload, after the capacity of load is lower than the rated power then output voltage will back to rated value, it ensures the UPS will not shut down by abrupt overload which caused by surging current during the computer is working and other equipment is added.
6. Short circuit protection
When the mis-operation caused the load short circuit or computer failure (such as power tube breakdown of switch) cause short circuit, the UPS will shutdown automatically for protection.
7. The low current switch
This UPS adopts low current switch to extend the service life which is longer than conventional battery and high current switch in AC current path.
8. Automatic charging
There are two charging mode, charging time is faster than ordinary charging mode, higher efficiency, and greatly prolonging the service life of the battery.
9. With a bypass output
Independent bypass output socket for external printers or scanners of computer peripherals, with surge protection of the load.
Photo shows:
Send Inquiry to This Supplier
You May Also Like
-
Eaton 9px6ki 9px 6kVA 1: 1 UPS Online Rack/Tower Online UPSNegotiableMOQ: 1 Piece
-
Uninterruptible Power SupplyNegotiableMOQ: 2000 Sets
-
Sales Promotion High Quality 110V 220 V Single Three Phase Uninterruptible Power Supply Online UPS SystemNegotiableMOQ: 1
-
AVR Intelligent Voltage RegulatorUS$ 300 - 5,000MOQ: 1 Piece
-
Online UPSNegotiableMOQ: 5 Sets
-
12V120Ah LiFePO4 Smart Battery for UPSNegotiableMOQ: 1 Set
-
Socomec UPS Uninterrupted Power SupplyNegotiableMOQ: 1
-
UPS Express to BANGLADESH From ShenzhenUS$ 1 - 20MOQ: 1 Kilogram
-
2016 Canton Fair Gel Battery 12v 150ahUS$ 155.00 - 160.00MOQ: 50 Pieces
-