1phase1-20k Online UPS
Specifications
1.single phase UPS, 6~20kVA2.high input PF(0.99) and output PF(0.9),
3.low THDi, high efficiency
4.big LCD display.
| HT1106S | HT1106L | HT1110S | HT1110L | HT1115L | HT1120L | |
| INPUT | ||||||
| Cold Start | YES, default frequency=50Hz or settable | YES, default frequency=50Hz or settable | YES, default frequency=50Hz or settable | YES, default frequency=50Hz or settable | ||
| Acceptable Input Voltage | 50%~125%(220VAC/230VAC/240VAC) | 50%~125%(220VAC/230VAC/240VAC) | 50%~125%(220VAC/230VAC/240VAC) | 50%~125%(220VAC/230VAC/240VAC) | ||
| 100% load@80%~125% | 100% load@80%~125% | 100% load@80%~125% | 100% load@80%~125% | |||
| 90% load@70%~80% | 90% load@70%~80% | 90% load@70%~80% | 90% load@70%~80% | |||
| 80% load@60%~70% | 80% load@60%~70% | 80% load@60%~70% | 80% load@60%~70% | |||
| 65% load@50%~60% | 65% load@50%~60% | 65% load@50%~60% | 65% load@50%~60% | |||
| Phase | Single phase in,single phase out | Single phase in,single phase out | Three phase in,single phase out | Single phase in,single phase out | ||
| Transfer Voltage Range | ||||||
| -Line low transfer | 110VAC/115VAC/120VAC | 110VAC/115VAC/120VAC | 110VAC/115VAC/120VAC | 110VAC/115VAC/120VAC | ||
| -Line low recovery | 116VAC/122VAC/127VAC | 116VAC/122VAC/127VAC | 116VAC/122VAC/127VAC | 116VAC/122VAC/127VAC | ||
| -Line high transfer | 275VAC/288VAC/300VAC | 275VAC/288VAC/300VAC | 275VAC/288VAC/300VAC | 275VAC/288VAC/300VAC | ||
| -Line high recovery | 268VAC/279VAC/291VAC | 268VAC/279VAC/291VAC | 268VAC/279VAC/291VAC | 268VAC/279VAC/291VAC | ||
| Input Power Factor | ≥0.99 | ≥0.99 | ≥0.98 | ≥0.98 | ||
| Input Frequency Range | 40Hz - 70Hz | 40Hz - 70Hz | 40Hz - 70Hz | 40Hz - 70Hz | ||
| Generator | Support Any Generator | Support Any Generator | Support Any Generator | Support Any Generator | ||
| OUTPUT | ||||||
| Frequency adaptable | Settable | Settable | Settable | Settable | ||
| Power | ||||||
| -Power(kVA) max | 6 | 10 | 15 | 20 | ||
| -Power(kW) max | 5.4 | 9 | 13.5 | 18 | ||
| Output Voltage | ||||||
| -Waveform | Pure sine wave | Pure sine wave | Pure sine wave | Pure sine wave | ||
| -Nominal voltage | 220/230/240VAC | 220/230/240VAC | 220/230/240VAC | 220/230/240VAC | ||
| -Voltage regulation | ± 1 % | ± 1 % | ± 1 % | ± 1 % | ||
| -Transient response | ≤5% (50% - 100% -50%) | ≤5% (50% - 100% -50%) | ≤5% (50% - 100% -50%) | ≤5% (50% - 100% -50%) | ||
| -Transient recovery | ≤15ms (0% - 100% -0%) | ≤15ms (0% - 100% -0%) | ≤15ms(0% - 100% -0%) | ≤15ms(0% - 100% -0%) | ||
| -Voltage distortion | ≤1% THD, linear load | ≤1% THD, linear load | ≤1% THD, linear load | ≤1% THD, linear load | ||
| ≤ 5% THD, non-linear load | ≤5% THD, non-linear load | ≤5% THD, non-linear load | ≤5% THD, non-linear load | |||
| Output Frequency | ||||||
| -Synchronization range | settable,±3Hz default | settable,±3Hz default | settable,±3Hz default | settable,±3Hz default | ||
| -Slew rate | 0.5~5Hz/s,2 Hz/s default | 0.5~5Hz/s,2Hz/s default | 0.5~5Hz/s,2Hz/s default | 0.5~5Hz/s,2Hz/s default | ||
| -Battery mode | (50±0.05) Hz | (50±0.05) Hz | (50±0.05) Hz | (50±0.05) Hz | ||
| Transfer Time | ||||||
| -Line mode to battery mode | 0 | 0 | 0 | 0 | ||
| -Inverter to bypass | 0.1ms | 0 | 0 | 0 | ||
| Efficiency | ||||||
| -Line mode with battery full charged | 93.0% | 93.0% | 93.5% | 93.5% | ||
| -ECO mode | 98.0% | 98.0% | 98.0% | 98.0% | ||
| -Battery mode | 92.0% | 92.0% | 92.0% | 92.0% | ||
| Noise | <48dB@<70%load,<58dB@>70%load;1m away | <48dB@<70%load,<60dB@>70%load;1m away | 53dB@<70%load,<66dB@>70%load;1m away | 53dB@<70%load,<66dB@>70%load;1m away | ||
| Overload Capability (Line Mode) | 110%: Transfer to bypass after 60 mins. | 110%: Transfer to bypass after 60 mins | 110%: Transfer to bypass after 60 mins | 110%: Transfer to bypass after 60 mins | ||
| 130%: Transfer to bypass after 1 min | 130%: Transfer to bypass after 1 min | 130%: Transfer to bypass after 1 min | 130%: Transfer to bypass after 1 min | |||
| 150%: Transfer to bypass after 30s, shutdown after 1 min.(Line mode) | 150%: Transfer to bypass after 30s, shutdown after 1 min.(Line mode) | 150%: Transfer to bypass after 30s, shutdown after 1 min.(Line mode) | 150%: Transfer to bypass after 30s, shutdown after 1 min.(Line mode) | |||
| Overload Capability (Battery Mode) | 110%: Shutdown after 10mins (Battery mode) | 110%: Shutdown after 10mins (Battery mode) | 110%: Shutdown after 10mins (Battery mode) | 110%: Shutdown after 10mins (Battery mode) | ||
| 125%:Shutdown after 10s(Battery mode) | 125%:Shutdown after 10s(Battery mode) | 125%:Shutdown after 10s(Battery mode) | 125%:Shutdown after 10s(Battery mode) | |||
| >125%: Shutdown after 1s (Battery mode) | >125%: Shutdown after 1s (Battery mode) | >125%: Shutdown after 1s (Battery mode) | >125%: Shutdown after 1s (Battery mode) | |||
| Crest Ratio | 3:1 | 3:1 | 3:1 | 3:1 | ||
| BATTERY | ||||||
| Rating/Type | 12VDC/7Ah | Depend on the capacity of external batteries | 12VDC/9Ah | Depend on the capacity of external batteries | Depend on the capacity of external batteries | Depend on the capacity of external batteries |
| Quantity | 16 | 16 | 16 | 16 | ||
| DC Voltage | 192VDC | 192VDC | 192VDC | 192VDC | ||
| Back-up Time | 4mins @80% load | Depend on the capacity of external batteries | 3.5mins @80% load | Depend on the capacity of external batteries | Depend on the capacity of external batteries | Depend on the capacity of external batteries |
| Battery-Low Voltage | (176±3)VDC | (176±3)VDC | (176±3)VDC | (176±3)VDC | ||
| Charger | ||||||
| -Charging voltage | (220±1%)VDC | (220±1%)VDC | (220±1%)VDC | (220±1%)VDC | ||
| -Charging current (max) | 1A | 5A | 1A | 5A | 5A | 5A |
| -Charging time | 7h recharge to 90% | Depend on the capacity of external batteries | 8h recharge to 90% | Depend on the capacity of external batteries | Depend on the capacity of external batteries | Depend on the capacity of external batteries |
| Leakage current | <1mA | <1mA | <1mA | <1mA | ||
| INDICATOR & ALARM | ||||||
| Display | LED+LCD | LED+LCD | LED+LCD | LED+LCD | ||
| Alarm | Sounding once per second | Sounding once per second | Sounding once per second | Sounding once per second | ||
| Fault | Continuous beeping | Continuous beeping | Continuous beeping | Continuous beeping | ||
| INTERFACE | ||||||
| Smart RS232 | Standard Cable support INVT Power Monitor Software | Standard Cable support INVT Power Monitor Software | Standard Cable support INVT Power Monitor Software | Standard Cable support INVT Power Monitor Software | ||
| Dry Contactor | 5 Ports | 5 Ports | 5 Ports | 5 Ports | ||
| SNMP(option) | Power Managment from SNMP Manager and Web Browser | Power Managment from SNMP Manager and Web Browser | Power Managment from SNMP Manager and Web Browser | Power Managment from SNMP Manager and Web Browser | ||
| OPTION | ||||||
| ECO Kit | YES | YES | YES | YES | YES | YES |
| Long Parallel Cable | YES | YES | YES | YES | YES | YES |
| Parallel Kit | YES | YES | YES | YES | YES | YES |
| SNMP | YES | YES | YES | YES | YES | YES |
Send Inquiry to This Supplier
You May Also Like
-
Eaton 9px6ki 9px 6kVA 1: 1 UPS Online Rack/Tower Online UPSNegotiableMOQ: 1 Piece
-
Uninterruptible Power SupplyNegotiableMOQ: 2000 Sets
-
Sales Promotion High Quality 110V 220 V Single Three Phase Uninterruptible Power Supply Online UPS SystemNegotiableMOQ: 1
-
AVR Intelligent Voltage RegulatorUS$ 300 - 5,000MOQ: 1 Piece
-
Online UPSNegotiableMOQ: 5 Sets
-
12V120Ah LiFePO4 Smart Battery for UPSNegotiableMOQ: 1 Set
-
Socomec UPS Uninterrupted Power SupplyNegotiableMOQ: 1
-
UPS Express to BANGLADESH From ShenzhenUS$ 1 - 20MOQ: 1 Kilogram
-
2016 Canton Fair Gel Battery 12v 150ahUS$ 155.00 - 160.00MOQ: 50 Pieces
-
EverExceed 1-400KVA 3 Phase Low Frequency Online UPS, GBT Input Rectifier PowrNX For TelecommucationUS$ 5,311 - 42,295MOQ: 1 Piece