XINFU Specific Heat Of An Object
Specifications
Complete automatic calorimeter, automaticly stir, ignite, display status of process, alarm and print the result.GC106 Calorimeter is new developed model based on ZDHW-5 Calorimeter.
General Introduction of Specific Heat Of An Object
Heat capacity of the calorimeter temperature of the system is the amount of heat of the apparatus is increased by the absorbed heat 1 ℃, with the J / K expressed. If you want to increase the combustion temperature of the sample is calculated based on the calorific value of the sample should first know that the water temperature rises 1 ℃ need to absorb much heat.
Under High Pressure Oxygen Condition:
Put samples in hot-corrosion-resistant metal crucible.
Put this crucible in oxygen bomb and seal it.
Charge oxygen in the bomb until the pressure reach 3.0Mpa
Put oxygen bomb in and turn on the calorimeter, burn the sample.
The heat will pass to the water in cylinder.
Calorimeter can calculate the calorific value of samples according to measure the water temperature, cylinder and bomb.
Features of GC106
1. Complete automatic calorimeter, automaticly stir, ignite, display status of process, alarm and print the result.
2. High test accuracy, tesing result can display directly.
3. Easy to operate, do not need skilled experts to do the complex test.
4. Stable performance.
5. Adopts the most advanced clock chip, can display time, date, week. It can also record the test time and print it on the result of test. Clock system can work when there is no electricity.
6. Auto calculate the average value when there is more than 5 times data.
Working Principle of Specific Heat Of An Object
Stirrer is composed of mini electric motor, stir vane and stirring shaft. The stirring speed is stable. Inner cylinder frame is made of plexiglass or bakelite. Oxygen charger is special designed to work with calorimeter, it can completely avoid splash during the charging. The charging speed can be adjusted. It is very easy to operate.
Standard Reference
ASTM E711-87(2004): Standard Test Method for Gross Calorific Value of Refuse-Derived Fuel by the Bomb Calorimeter (Withdrawn 2004) ASTM D3180 - 1: Standard Practice for Calculating Coal and Coke Analyses from As-Determined to Different Bases ASTM E955 - 88(2009)e1: Standard Test Method for Thermal Characteristics of Refuse-Derived Fuel Macrosamples ASTM D3172 - 13: Standard Practice for Proximate Analysis of Coal and Coke
Main Specification
Heat Capacity 10500 J/K
Oxygen Bomb Capacity 300 ml
Oxygen Pressure 2.8~3.0 Mpa
Water Pressure 20 Mpa
Weight 2.5 kg
Dimension Φ86.2*181 mm
Outer Cylinder Capacity 17 L
Inner Cylinder Capacity 2.1 L
Display Range 0.000~65.000 ℃
Response Time <1 s
Resolution 0.001 ℃
Linearity <0.08% (Heating Rate 5℃)
Temp Accuracy 0.003℃ (Heating Rate 5℃)
Working Voltage AC:220±10%V
Operating RH <80%
Ignite Voltage AC:24V
Ignite Time 5 s
Total Weight 21.5 kg
Send Inquiry to This Supplier
You May Also Like
-
Endress+Hauser E+H Compact Conductivity Device Smartec CLD18-BGGENegotiableMOQ: 1 Piece
-
2017 Latest High Quality Transformer Oil Dielectric Strength BDV TesterUS$ 1500 - 3500MOQ: 1 Set
-
Universal Testing MachineNegotiableMOQ: 2500 Pieces
-
Computer Control Hydraulic Universal Testing MachineNegotiableMOQ: 1 Set
-
Hydraulic Plastic Flange Connections Cover Plugs SHF SeriesUS$ 0.22 - 0.28MOQ: 2500 Pieces
-
Gates 550C 550U U550 U-550 U508 U-508 Japan Unitta U-550 Belt Tension Meter New U-508 Belt Tension Meter Upgraded Version U550US$ 1 - 900MOQ: 1 Piece
-
Vertical Rod Type Floor-type Electrostatic Discharge Tester / Electrostatic Discharge Device for Human BodyUS$ 20 - 93MOQ: 1 Piece
-
Analytical Balanace.scale ,weichengya Laboratory SupplierUS$ 10 - 35MOQ: 10 Sets
-
Smart MD-3051 Online Density Meter With 4-20mA OutputUS$ 2,380 - 2,500MOQ: 1 Unit
-
5W-300W Sun Simulator Watt Testing 30% Off / Xenon Lamp Sun Simulator Free Sent / Sun Simulator TestingUS$ 7,500 - 10,000MOQ: 1 Set