Dental Autoclave Vacuum Steam Sterilizer Class B LCD Display
LCD Large screen Dental Steam Autoclave
ALFD-SII Dental autoclave
1. European Class B standard, It adopts B-wclass(prE-13060),
with 3-times vacuum pulse preceding vacuum drying
2. Residual humidity is <0.2, vacuum measurement reaches -0.96bar
3. It sterilize miscellaneous packed or unpacked medical instruments on 121/134 ℃
4. working power : 110v- 240v. 23L: 1800W; 18L:1800W
5.Use imported&advanced 16 bit microprocessor.easy to operate .Most suitable for the dept of Stomatology, Ophthalmology ,Surgery and Lab .
6.With alarm system for wast water tank, avoid the waste water to enter intoe sterilizing circulation,make the sterlizing completely .
7.Precise LCD display and advanced self-test system ensure you get the working data freely .
8.Double lock door system for safety during operating.
9. The new desgin of water tank is on the top , easy to clean .
10.Optional inbuilt mini-printer or USB connector to record the process of sterilizing .
Application : suitable sterilizing wrap,unwrap ,solid ,porous, hollow device .
Model |
Power |
Tank (Liters) |
Size (mm) |
Chamber (mm) |
Package (cm) |
G.W (Kg) |
ALFD-SII12 |
1800W |
12 |
445*550*395 |
Φ200*368 |
67*55*50 |
46 |
ALFD-SII16 |
1800W |
16 |
445*550*39 |
Φ240*360 |
67*55*50 |
47 |
ALFD-SII18 |
1800W |
18 |
445*550*395 |
Φ245*355 |
67*55*50 |
48 |
ALFD-SII23 |
2000W |
23 |
445*640*395 |
Φ245*465 |
72*52*50 |
53 |
1. The autoclave must be placed on the horizontal working base.
2. Must use the distilled water for the purpose of lasting the working life.
3. There shall be no clog to the air cooling window on the outer surface.
4. The object apparatus to be sterilized shall be placed on the device plate with enough clearance retained in favor of the air circulation inside the sterilizing room.
5. Empty the water inside the cooling water collecting tank frequently. Usually, the cooling water collecting tank shall be emptied once the water storing tank emptied.
6. Must revolve the door handle to the teminal side while working.
7. Don't open the door of autoclave when seeing the "0" displayed on the pressure indicator.
8. Not be too closed to the door of the autoclave in case of scald when open the door.
9. Shut off the power before discharging/installing the sealing ring, and the work shall be carried out after further sufficient cooling in case of scald.
10. Don't drag or drop the autoclave during relocation period of the autoclave.
11. The protecting ground shall be reliable.
12. Equipment must be used away from teh magnetic field.
13. Equipment life end, dealing with to local environmental protection laws and regulations.
Advantages we have,
1. Experienced sales products supplier .
2. Professional Designer and sales department for your service .
3. Alibaba Golden supplier ,factory recognized by CE and ISO .
4. 24 hours on line ,all questions will reply you within 24 hours in time .
Send Inquiry to This Supplier
You May Also Like
-
Dental ChairUS$ 1260 - 3750MOQ: 1 Piece
-
Customized Europe Modern Hospital Dental Care Use Dentist EquipmentNegotiableMOQ: 1 Set
-
Easy to Clean Vary Oral Care Needs Portable Dental IrrigatorUS$ 16 - 35MOQ: 1 Set
-
2015 New Style Dental Bench In FurnitureUS$ 600 - 1,500MOQ: 5 Sets
-
3 Ply Disposable Waterproof Colorful Dental Bib With PE FilmUS$ 10 - 15MOQ: 200 Cartons
-
Denture Storage Box: Keep False Teeth CleanerUS$ 0.225 - 1.225MOQ: 5000 Pieces
-
KMJ24 Saw-MateUS$ 350 - 650MOQ: 1 Piece
-
High Quality Stamping Metal Bracket for Medical Apparatus and InstrumentsUS$ 0.6425 - 0.6425MOQ: 1000 Pieces
-
15 Years Factory High Quality Dental Chair Spare PartsUS$ 0.01 - 100MOQ: 50 Pieces
-
Power Tooth Stain Remover and Tooth WhitenerUS$ 3.6 - 4MOQ: 200 Sets