The Transformer is a electrical device which is designed to change one AC Voltage to another by magnetic induction. It "Steps-up"or "Steps-down" voltage in order to match incoming supply voltage from the utility to the voltage required by the user's end products. Common international voltages include 110V, 220V, 380V, and 415V. Typical USA supply voltages are 120V, 208V, 240V, 277V, 480V (and 575V in Canada).
Model | Capacity (VA) | Voltage Combination | Case Qty.(Pcs) | Item code |
Primary(V) / Secondary(V) | ||||
BK-50 | 50 |
440/220 240/24 220/24 220-380/110-60-48-24 380/220-110
| 24 | 82100050 |
BK-100 | 100 | 24 | 82100100 | |
BK-150 | 150 | 16 | 82100150 | |
BK-200 | 200 | 12 | 82100200 | |
BK-250 | 250 | 6 | 82100250 | |
BK-300 | 300 | 6 | 82100300 | |
BK-400 | 400 | 4 | 82100400 | |
BK-500 | 500 | 4 | 82100500 | |
| BK-700 | 700 | 1 | 82100700 | |
BK-1000 | 1000 | 1 | 82101000 | |
BK-1500 | 1500 | 1 | 82101500 | |
BK-2000 | 2000 | 1 | 82102000 |
Volt amps (VA) is the effective power rating for a transformer. In the perfect transformer, the voltage and current (combined) applied at the primary will exactly equal the voltage and current (combined) on the secondary(s). Efficiency is a measure of a transformer's ability to deliver the input power to the load. Efficiency is expressed as a percent by:
% = ( PO / PI ) x 100
where; PO = Output power, PI = Input power, % = Efficiency
1. Read the transformer's secondary winding rating (printed or tagged on the transformer case). This should give a rating such as 5 V , 500 mA. Multiply the voltage times the current to receive the VA.
Example: 5 V times 500 mA (or 0.5 A) equals 2.5 VA
2. Convert the secondary winding VA value to the primary winding VA rating as the equation VA (primary) equals VA (secondary) or VA (p) = VA (s). For the example of a 2.5 VA secondary, if the primary voltage is 120 V the current will be A (p) = VA (s)/V(p). Giving A(p) = 2.5 / 120 = 0.020833 (roughly 21mA). This is the calculation for a single input winding/single output winding transformer.
3. Add the separate VA ratings for a transformer with multiple secondary windings.
For secondary winding 1 = 5 V at 500 mA
Secondary winding 2 = 24 V at 100 mA
Total secondary VA = ( 5 x 0.5 ) + ( 24 x 0.1) = 4.9 VA
Primary VA will still equal the total secondary VA.
Dixsen was born in 1992, we are a professional manufacturer focuses on low voltage components like Current and voltage Transformers, Transformers, Meters, MCCBs, MCBs, AC Contactors, Fuse and Bases, Relays and sort of things. We locate in Wenzhou city, Zhejiang province, where is quite close to Shanghai and Ningbo port. A 15000 square meter area is divided into workshop zone and office zone, 430 employees are currently making their great efforts in that area for Dixsen brand.
Send Inquiry to This Supplier
You May Also Like
-
ABB DTAX701A 61430001-WMNegotiableMOQ: 1 Piece
-
WOODWARD 8901-457 – Industrial Control Module for Engine/Turbine Protection and Speed ManagementNegotiableMOQ: 1 Bag
-
Low Voltage Draw-out Type Switch CabinetNegotiableMOQ: 50 Sets
-
Motorola MVME167-34B VME Bus Single-board ComputerNegotiableMOQ: 1 Piece
-
ABB DSTX180 3BUR980025R1NegotiableMOQ: 1 Piece
-
HONEYWELL DSTX170 57160001-ADKNegotiableMOQ: 1 Piece
-
ABB DSTS103 DSTS 103NegotiableMOQ: 1 Piece
-
HONEYWELL DTDX707A 61430001-WGNegotiableMOQ: 1 Piece
-
ABB DSTK165 26390603-ANNegotiableMOQ: 1 Piece
-
HONEYWELL CC-IP0101 51410056-175NegotiableMOQ: 1 Piece