Manufacturer DP-88-250/5 Split Core
Current Transformer 250/5A
Model:DP-88-250/5
Current Transformer (CT) is used to transform the high AC current to small easily manageable values. They're connected with the Panel Meter or Relay and they can help to measure the current or protect the equipments. Low voltage current transformers are manufactured as of two types for measuring CT.
- Measuring CT: Measuring current transformers are constructed to feed on other low voltage apparatus such as measuring instruments, relays, watt-hour meter (KW meter) and these type of current transformers are mainly used 0.5 and 1.0 class to transfer the current from highest rated current to rated secondary current.
- Protection CT: Protection current transformers are constructed to feed the protection relay. These type of current transformers are mainly used 5P. (Customer supplied when required.)
- Current Ratio.......................................................................250/5A
- Accuracy..............................................................................Class 1.0
- Burden.................................................................................See Selection Form.
- Security Factor....................................................................FS<5
- Max System Voltage..........................................................720V AC
- Test Voltage........................................................................3kV AC.(1 min.)
- Frequency............................................................................50/60Hz
- Rated Short-time Thermal Current (Ith)............................Ith=60XIn
- Rated Dynamic Current (Idyn)...........................................Idyn=2.5XIth
- Continuous Overload..........................................................1.2 XIn
- Working Temperature..........................................................-25°C~+50°C
- insulation Rating...................................................................Class B
- Housing Self-extinguishing Class.......................................VO.
- Bus-bar Support Mounting...................................................Provided.
- Panel Mounting......................................................................Provided.
- Hinged Sealable Terminal Cover........................................No Provided.
- Standards...............................IEC/EN60044-1,VDE0414-44-1,BS3938,BS7626
- Item Condition.......................................................................Brand New.
- Quality Assurance.................................................................24 Months.
- Sample Service......................................................................Provided.
| Item | Current Ratio | Rated Burden (VA) | Case Qty. | |
| Model | (A) | Class: 0.5 | Class: 1.0 | (Pcs) |
| DP-88 | 250/5 | - | 1.5 | 10 |
| 300/5 | - | 1.5 | 10 | |
| 400/5 | - | 2.5 | 10 | |
| 500/5 | 1.5 | 2.5 | 10 | |
| 600/5 | 2.5 | 5 | 10 | |
| 750/5 | 2.5 | 5 | 10 | |
| 800/5 | 3.75 | 5 | 10 | |
| 1000/5 | 5 | 10 | 10 | |

Send Inquiry to This Supplier
You May Also Like
-
Three Phase Power Supply System 1000kVA 10kv 24kv 35kv Dry Type TransformerNegotiableMOQ: 50 Sets
-
Bently Nevada 21000-28-05-00-75-01-02NegotiableMOQ: 1 Piece
-
3500/53 133388-02 Monitoring ModuleNegotiableMOQ: 1 Bag
-
Motorola MVME167-34B VME Bus Single-board ComputerNegotiableMOQ: 1 Piece
-
Low Noise Low Loss Dry-Type Cast Coil Transformer 2450kv 10kv CustomizedNegotiableMOQ: 50 Sets
-
Three Phase Dry Type Voltage Transformer 415V 400V 380V to 220V AutotransformerNegotiableMOQ: 50 Sets
-
35 Kv Epoxy Resin Casting Dry Type Power Transformer and Distribution TransformerNegotiableMOQ: 50 Sets
-
Manufacturer Supply 500kVA 35kv Amorphous Alloy Dry Type Power Transmission Distribution TransformerNegotiableMOQ: 50 Sets
-
2500KVA 11KV Three Phase Cast Resin Dry Type Distribution TransformerNegotiableMOQ: 50 Sets
-
Epoxy Casting Dry Type Power Distribution Electric High Voltage Frequency Transformer for Power PlantNegotiableMOQ: 50 Sets