Home > Instruments & Meters > Test Instrument > Test Machine > HIOKI CLAMP ON POWER LOGGER PW3365

HIOKI CLAMP ON POWER LOGGER PW3365

HIOKI CLAMP ON POWER LOGGER PW3365 photo-1
Negotiable MOQ: 1 Piece (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Place of Origin:
Japan
Brand Name:
HIOKI
Model Number:
PW3365
Payment & Shipping
Payment Methods:
Port of Shipment:
XI'AN
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin Japan
Brand Name HIOKI
Model Number PW3365
Power Other, 50/60 Hz
Usage Other, multi-channel power measuring devices

Specifications

1.The PW3365-20 takes safety and convenience
2. multi-channel power measuring devices utilizing clamp sensor

Overview:

 

• The PW3365-20’s dedicated voltage sensor delivers the world’s first no-metal-contact measurement.
• Measure between 90V to 520V in a single 400V range
• Broadly applicable for many jobs, including leakage current measurement (an optional clamp-on leakage sensor supports measurements as low as 50 mA)
• Store months of data on SD cards
• The QUICK SET function guides you in making the right connections

 

Specifications:

 

Basic specifications (Accuracy guaranteed for 1 year)

Measurement line & number of circuits 50/60 Hz, Single phase 2 wires (1/2/3 circuits), Single phase 3 wires (1 circuit), Three phases 3 wires (1 circuit), Three phases 4 wires (1 circuit), Current only: 1 to 3 channels
Measurement items Voltage/current RMS, voltage/current fundamental wave value, voltage /current fundamental wave phase angle, frequency, voltage waveform peak (absolute value), current waveform peak (absolute value), active/reactive/ apparent power, power factor (lag/lead) or displacement power factor (lag/lead), active energy (consumption, regeneration), reactive energy (consumption, regeneration), active power demand quantity (consumption, regeneration), reactive power demand quantity (lag/lead), active power demand value (consumption, regeneration), reactive power demand value (lag/lead), power factor demand, energy cost
Voltage ranges 400 V AC
Current ranges 500.00 mA to 5.0000 kA AC (depends on current sensor in use),
50.000 mA to 5.0000 A AC (Leak clamp on sensor only)
Power ranges 200.00 W to 6.0000 MW (Depends on voltage/current combination and measured line type)
Basic accuracy Voltage : ±1.5% rdg. ±0.2% f.s(combined accuracy with PW3365-20 + PW9020)
Current : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy
Active power : ±2.0% rdg. ±0.3% f.s. + clamp sensor accuracy (at power factor = 1)
Display update rate 0.5 sec (except when accessing SD card or internal memory, or during LAN/USB communication)
Save destination SD Memory card, or internal memory at real time
Data save interval 1 sec to 30 sec, 1 minute to 60 minutes, 14 selections
Save items Measurement value save: Average only / average, maximum, minimum value
Screen copy: BMP form (saved every 5 min. at minimum interval time)
Waveform save: Binary waveform data
Interfaces SD memory card
HTTP server function, remote settings via communication program, data download
USB 2.0: When connected to a PC, the SD Card and internal memory are recognized as removable storage devices, remote settings via communication program, data download
Pulse output: proportional to active power consumption when measuring integral power consumption, Isolated open-collector signal
Functions Connection check, Quick Set navigation guide, clock
Power supply AC adapter Z1008: (100 to 240 V AC, 50/60 Hz), 45 VA (including AC adapter)
Battery pack 9459: (DC 7.2 V, 3 VA, charging time 6 hr 10 m), 5 hours of continuous use (with back light off)
Dimensions and mass 180 mm (7.09 in)W × 100 mm (3.94 in)H × 48 mm (1.89 in)D, 540 g (19 oz) without PW9002
180 mm (7.09 in)W × 100 mm (3.94 in)H × 68 mm (2.68 in)D, 820 g (28.9 oz) with PW9002
Accessories Safety Voltage Sensor PW9020 ×1 set, AC adapter Z1008 ×1, USB cable ×1, Instruction manual ×1, Measurement guide ×1, Color spiral tubes ×1 set: red, yellow, blue/four each, Spiral tubes for grouping clamp sensor cords ×10

 

 

Current measurement

For power or load current measurement (1 sensor necessary for single-phase measurements, and 2 or 3 sensors required for 3-phase measurements)

CONNECTION CABLE 9219


Connect with the 9695-02/ -03, Output BNC terminal 

CLAMP ON SENSOR 9669


• 40Hz to 5kHz • Phase: 45Hz to 5kHz • 1000A AC rated input • 0.5mV AC/A output • φ55mm (2.17in) dia. 

CLAMP ON SENSOR 9660


• 40Hz to 5kHz • Phase: 45Hz to 5kHz • 100 A AC rated input • 1 mV AC / A output • φ 15 mm (0.59 in) core dia. 

FLEXIBLE CLAMP ON SENSOR CT9667


• 10 Hz to 20 kHz (±3dB) • 5000A/500A AC rated input • 500 mV/f.s. output • φ254 mm (10.0in) dia. 

CLAMP ON SENSOR 9661


• 40Hz to 5kHz • Phase: 45Hz to 5kHz • 500A AC rated input • 1mV AC/A output • φ46mm (1.81in) dia. 

CLAMP ON SENSOR 9694


• 40Hz to 5kHz • Phase: 45Hz to 5kHz • 5 A AC rated input • 10 mV AC / A output • φ 15 mm (0.59 in) core dia. 

CLAMP ON SENSOR 9695-02


• 40 Hz to 5 kHz • Phase: 45 Hz to 5 kHz • 50A AC rated input • 10mV AC /A output • φ15mm (0.59in) dia.

CLAMP ON SENSOR 9695-03


• 40 Hz to 5 kHz • Phase: 45 Hz to 5 kHz • 100A AC rated input • 1mV AC/A output • φ15mm (0.59in) dia. 
 

Leak current

For leak current measurement (not capable of power measurement)

CLAMP ON LEAK SENSOR 9675


• 40 Hz to 5 kHz • Rated 10 A AC • 100 mV AC/A output • φ30 mm (1.18 in) dia. 

CLAMP ON LEAK SENSOR 9657-10


• 40 Hz to 5 kHz • Rated 10 A AC • 100 mV AC/A output • φ40 mm (1.57 in) dia. 
 

Adapter

For clamp sensor

CLAMP ON ADAPTER 9290-10


• Primary 1000A, secondary 100A (1/10 ratio) output • Superior phase angle characteristics for power 
 

Voltage measurement

*PW9020 ×4 pieces are bundled, additional single sensors also available

 

SAFETY VOLTAGE SENSOR PW9020


For PW3365s, 3 m (9.84 ft) length 
 

Storage media

SD Card Precaution Use only SD Cards sold by HIOKI. Compatibility and performance are not guaranteed for SD cards made by other manufacturers. You may be unable to read from or save data to such cards.

SD MEMORY CARD 2GB Z4001


For storing measurement data 
 

Power supply

*Z1008 is bundled, Model 9459 is a replacement battery pack included with the Battery Set PW9002.

BATTERY PACK 9459


NiMH, Charges while installed in the main unit 

BATTERY SET PW9002


Battery case and Battery Pack 9459 Set 

AC ADAPTER Z1008


100 to 240V AC 
 

Other options

C1005 store Current sensor ×2, Voltage sensor ×3 pieces

LAN CABLE 9642


Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length 

CARRYING CASE C1005


For PW3360/3365 series, for storing options 

POWER LOGGER VIEWER SF1001


• Easy graphical processing of measurement data saved with the PW3360/3365 series, 3169 series on a PC 

CARRYING CASE C1008


For PW3365 series, for storing Current sensor ×3, Voltage sensor ×4 pieces 

 

 

 

 

HIOKI CLAMP ON POWER LOGGER PW3365

 

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer, Trading Company
Year Established
2010
Factory Size
Below 1,000 square meters
Total Employees
51 - 100 People

Recommended Categories

Explore top categories and find suppliers for your specific needs