Specifications

XYZP-IB Computer Intermediate Frequency Therapeutic apparatus is developed on the basis of intermediate frequency electrical sti

1. Normal working conditions

1. 1 Environment temperature: 5°C~40°C.

1. 2 Atmosphere pressure: 70Kpa~406Kpa.

1. 3 Relative humidity: ≤80%.

1. 4 Power source: 220V±22V,50Hz±1Hz.

2. Working frequency

The working frequency of the therapeutic apparatus is 2KHz~6KHz, and its error is ±10%.

3. Output current

3. 1 The output current is continuously adjustable within 0~99mA.

3. 2 The stability of the output current is not more than ±5%.

4. Modulation frequency range

The modulation frequency range of the therapeutic apparatus is not narrower than 0~150Hz.

5. Diathermanous operating frequency

The diathermanous operating frequency is 2Hz, and its permitted error is ±10%.

6. The surface temperature of the electrode plate

When the diathermanous function is in use, the surface temperature of the electrode plate is within 38°C~50°C(below 23°C±2°C).

7. Output wave form

Output wave form: Sine wave, square wave, triangle wave, index wave, the peak wave, the sawtooth wave, continuous wave, condensation wave, monophase fixe.

8. Timing requirements

8. 1 The timing is 20 min and its error is not more than 1 min.

8. 2 Normally, at the end of treatment, the therapeutic apparatus will stop outputting by itself and give a prompting sound.

9. Input power: 44VA±10%.

10. Output channel: single channel, intermediate frequency, diathermanous output;

11. Safety type: class II, type BF.

12. Fuse: 2A,Φ5×20.

13. Storage environmental conditions: the packaged therapeutic apparatus shall be stored in an airy room with a temperature of -40°C~55°C, a relative humidity less than 93%, and having no corrosive gas.