CO2 laser treatment using sealed-off CO2 laser, the output invisible infrared laser beam is characterized by small, high energy density; Laser beam output by the focusing mirror, the focal point of the target tissue can produce high temperature gasification, can be used for cutting, burning; Direct the laser beam output, low energy density, can be the target tissue coagulation surgery; CO2 laser output of the laser transmission through optical arm, with a variety of
headpiece, for a variety of surgery.
CL30
1. Treatment principle
The CO2 surgical laser system –CL30 are CE and ISO certificate approved. It adopts sealed off CO2 laser which transmits laser through the guiding light joint arm. The output is invisible infraredwhich wavelength is 10600nm, the characteristic is a good direction, the energy density is high.
The laser transmitted through focus lens, the high temperature produced by the focus spot can gasify, cut and cautery the target organ. If the laser transmitted without through the focus lens, the energy density is lower, it can be used for freeze.If the laser transmitted through beam expander, the instrument can be used in irradiating physical therapy.
2. Construction Performance
2.1 Laser tube(lasers for short)
The laser make of glass tube filled with CO2 air. The back end sticks the whole reflection mirror slice and the front end sticks the exportation window mirror slice which consists of laser cavity resonator. The electrode is installed on the side.
When the electrode of lasers connect with high voltage and electric current, the CO2 gas is motivated so as to produce laser and be sent out from the exportation window of the lasers. There are cooling pipe line, cooling with water inside of its.
2.2 The guiding light joint arm
It consists of even joints and a guiding light tube. There are laser reflector slices in the joints. Laser beam through focus lens outputs in the interval after reflecting for many times. The outlet can be assembled with focused lens, all kinds of operation head- knife and expanding beam lens.
Application of head-knife,
Focus Lens of laser articulated arm F = focal length of 100mm (1F).It
(F=100mm) can be used with cutting head-knife (1F) or ENT head-knife, please
make sure the output end is away from the skin around 5mm.
Other head- knife’s length over 100mm (as:1.3 F, 1.6 F, 2 F), far away from the focus, more big spot, the density will be lower, so the heads can be used for solidification surgery.( offering 5pieces headknife,5of them is backup).
2.3 Power supply and Control parts
It is combined with switching power supply and computer control parts. Adjusting the current of switching power supply can control the output power of the lasers. Control parts are made up of the Micro-computer control panel, data collect board, Liquid crystal display and touch panel
2.4 Cooling circle system
The large amount of heat will happen when the instrument works. We use the inner circle system to cool off. The pure water is in the tank, which is sent by pump to the laser pipes and reflows to the tank through flow controller.
2.5 Instruction laser (DIODE),
When the status is in STA-BY, press the key A.BEAM to select if using the red indicative laser or not when operating. Press the key Continuum to select the output status of instruction laser.
2.6 Instant stop button
Press this button to cut off the power and stop the laser output when the foot switch is out of work or other problems happen. Turn the button clockwise to spring out it so as to restore original position when the problems settled.
2.7Control switch(foot step switch)
The foot step switch of the instrument is a kind of drop– proof type suiting for the common laser clinic. The water- proof foot step switch is suit in the operating room.
2.8 Protecting cooling water from breakdown
If the circle cooling water appears breakdown, the laser tube will be damaged. So the instrument lacks water, or water temperature is over 45 °C, the computer will cut off the power supply and produce the alarm sound automatically.
2.9 safety door link lock
To assure safety on operating, the door must be shut. Then connect the switch with “the door link socket" of the instrument. If the door of the operation room is opened when operating, the instrument will stop transmitting laser.
3. Application
The equipment is featured by reasonable construction, stable performance, and safety, and reliability.
The CO2 laser therapy apparatus model is suitable for used extensively in such departments as dermatological, ENT, gynecological and general surgical for cautery and vaporization treatment. This machine is well suited to usage by different levels of hospitals and medical centers.The detailed using scope is as following,
- Dermatology: facial cosmetology, body freckle, nevus, tumour, wart, skin cancer, the instrument can excise anything superfluous or useless in order to make people strong and handsome and to prevent pathological changing.
2. E.N.T: all kinds of rhinitises, nose polyps, pharyngitises, oral hemangiomas.
3. Ophthalmology: orbit tumour, eyelid, sty, double blood skin.
4. Gynecology: chronic cervicitis, valvar angiofibromata, cervical erosion, leukoplakiavulvae, excesion uterus polyp, cervical carcinoma in situs, etc.
5. General surgery: haemorrhoids, aal fissure and anal fistula, phimosis, V.D. etc.
6. Physical therapy: inflammatory mass, chronic ulcers, vasculitis, scapulohumeral periarthritis , soft tissue contusion, wound infection.
7. Others: underarm odour, corn, ulcer.
4. Technique parameter
4.1 Laser wavelength: 10600 nm, Inaccuracy ≤±5%
4.2 Laser beam radiation angle: <10 mr
4.3 Color computer screen: 8 inch touch screen color,
4.4 Focal spot diameter: <0.5mm
4.5 operation mode: CWsingleRepeat pulseUltra pulse
4.6 articulated arm: 7-joint spring-balanced
4.7 Working radius: 130cm
4.8 Aiming beam Diode laser: 635nm3mW
4.9 Ultra pulse width: 0.1—2mS
4.10 pulse recurrence rate: 5-500 mS
4.11 Tissue Exposure Modes: CW Repeat pulseUltra pulse
4.12 The distinction:
Type |
Output power |
Volume(mm) |
CL30 |
≥25W |
360x 360x 1050 |
4.13 Divergence: TEM 00
4.14 Terminal output focus lens: Focus =100 mm
4.15 Instrument rating current: 20 m A
4.16 Power input: 400VA;
4.17 Normal work conditions:
a).Environment temperature: 10 °C— 30 °C ;
b).Relative humidity: 30% — 70%;
c).Atmospheric pressure: 70kPa— 106kPa;
d).Power supply: AC 230V or 110V
4.18 Packing L×W×H: 50*50*120cm
4.19 Gross Weight: 40kg (Net weight 30kg)
For fractional,
SCAN FRACTIONAL LASER PRINCIPLE
Scanning laser is controlled by the computer, laser beam on the skin that hit points of light are arranged in all kinds of graphics,
In fact laser beam not be divided into many points, So, Each of the points of light in diameter of 0.2-0.3 mm, this is the current technology can make the smallest points of light
As each time 5 milliseconds, glowing stay type 60 points to need 300 milliseconds,
Because of the laser stay time is short, the main role in the epidermis,
But, it can arrange more closely,
So, scanning laser available skin peeling surgery and Used for change skin beauty
SCAN FRACTIONAL LASER SPECIFICATION
Wavelengths: 10.6microns
Mode Structure: TEM00
Control system: 8 inch touch screen color, footswitch
Power to tissue: 25W
Laser operation modes: Fractional, Magic, Single, Repeat Pulse & CW.
Aiming beam: Diode laser 650nm 3mW
Beam delivery system: 7-joint spring-balanced articulated arm
Working radius: 130cm
Cooling system: Water closed-cycle
Electrical: 230VAC/50Hz or 110VAC/60Hz
Package dimensions: 50*50*120cm
Gross weight: 40kg
Net weight: 30kg
Warranty: 1 year
Scanner Graphics: Square or rectangle, Polygon, round, triangle
Working mode: Fractional (Magic Pulse Technology)
Dot quantity: 1-10000 dots at most
focus size: 0.2mm
Point spacing: 0.1--2.6mm
Duty time: 0.1-10ms
Idle time: 1ms -1s
Repeat: 1--20
Treatment size: 20x20mm (adjustable)
Menus: 5
Point spacing : 1mm
SCAN FRACTIONAL LASER APPLICATIONS
Acne scars, nevi, tattoo, dark spots, warts, removal
Wrinkles reduction or removal (face, forehead, around lips, neck)
Hemangioma, lipoma cutting
Lleukoplakia vulvae treatment
Cervical erosion treatment
Circumcision treatment
Condyloma acuminatum treatment
Aesthetics Surgery: skin rejuvenation, eyelift, facelift, etc
Shapes
Fractional head
Send Inquiry to This Supplier
You May Also Like
-
Medical Spatula White Wood Tongue DepressorUS$ 22 - 45MOQ: 1 Carton
-
Bipolar Coag,bipolar Cut Two Modes Cheap High Frequency Electrotome PriceNegotiableMOQ: 1 Set
-
Percussion HammersNegotiableMOQ: 1
-
Factory Body Massage Muscle Injury and Pain Relief Laser Surgical InstrumentsUS$ 350 - 680MOQ: 1 Set
-
Stamping Battery Box in Medical Equipment InstrumentUS$ 2.9 - 3.8MOQ: 500 Pieces
-
YDZ-30 Biological Storage Cryogenic Storage Tank Dewar Container Auto Tool With Low PriceUS$ 990 - 1,200MOQ: 1 Set
-
Max Waves Infrared Comb InstrumentsUS$ 40 - 41MOQ: 100 Pieces
-
Top in China Keling Medical X-RAY OBSERVATION LAMP (unifold)US$ 40 - 90MOQ: 10 Sets
-
High Quality Oem Service Medical Instrument AccessoriesUS$ 10 - 15MOQ: 100 Pieces
-
Stainless Steel Medical Surgical Instruments Manufacturer With Good PriceUS$ 0.1 - 5MOQ: 1000 Pieces