Hospital Waste Burning Disposal Incinerator

Hospital Waste Burning Disposal Incinerator photo-1
Hospital Waste Burning Disposal Incinerator photo-2
US$ 12,100 - 12,580 MOQ: 1 Set
Key Specifications
Get Latest Price
Place of Origin:
Shandong, China
Brand Name:
YiMei
Model Number:
LDF-100
Payment & Shipping
Payment Methods:
Port of Shipment:
QINGDAO
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin Shandong, China
Brand Name YiMei
Model Number LDF-100
Type Other, Solid waste treatment
 
Product Description

 

LDF series medical solid waste incinerator

LDF series medical waste incineration installation with the characteristic of small size, high efficiency and reasonable incineration, leading technology, higher harmless degree, is the ideal garbage treatment facilities apply to all kinds of hospital, hotel, station.

 

Design basis:

1.Furnace body type:Vertical closed furnace combustion chamber;

2. burning capacity:100-120kg/time ( daily burn 3-6times,each time consume  about 1 hour)

3. Ignition manner:automatic

4.fuel type:0# or-10# diesel;

5. feeding mode:Solid waste manual feeding

6. take ash manner :manual 

     7. furnace inner pressure: adopt negative pressure design, no back-fire,—3~—10mmH2O

 heat value: waste mix  1500kcal/kg ~2500kcal/kg,0# diesel 10000kcal/kg

9. flue gas treatment manner:

Gasification combustion chamber(first combustion chamber) + blower + mixed combustion chamber+high temperature secondary combustion chamber + flue gas purification room (calcium hydroxide filter brick) +exhaust fan  + independent chimney 

10.burning temperature:

First combustion chamber:  600-800℃ 

 Secondary combusition chamber:1500℃ 

Flue gas residence time≥2s

11.Combustion efficiency: ≥99.99%,

   12.Incinerator during operation to ensure system is in negative pressure condition, avoid harmful gas escape;

13. Glue gas discharge standard   GB18484-2001<Hazardous waste incineration pollution control standards>

 

Main features:

1. The gasifying incineration technology to be applied to the incineration injector, feeding container and other medical equipment as well as different paper slash, bandage, cotton column, different kinds of medical pollutants and various wastes discharged by hospitals and medical organization.

2. The gasifying incineration way is utilized and the rubbished produced each day is able to handle the one-off incineration treatment.

3. The gasifying incineration, mixed incineration, burn-out treatment and other technologies are used to make the content of the smog exhaust and dust lower than the discharge standard regulated by the nation.

4. Fully seal operation is adopted to be applied to dealing with the infectious medical waste and avoid the secondary pollution.

5. Small volume and site area.

6. The series of incinerator are divided into the fuel and gas kind which can be selected according to the different needs of the users.

1.Furnace body type:Vertical closed furnace combustion chamber;

2. burning capacity:100-120kg/time ( daily burn 3-6times,each time consume about 1 hour)

3. Ignition manner:automatic

4.fuel type:0# or-10# diesel;

5. feeding mode:Solid waste manual feeding

6. take ash manner :manual

7. furnace inner pressure: adopt negative pressure design, no back-fire,—3~—10mmH2O

heat value: waste mix 1500kcal/kg ~2500kcal/kg,0# diesel 10000kcal/kg

9. flue gas treatment manner:

Gasification combustion chamber(first combustion chamber) + blower + mixed combustion chamber+high temperature secondary combustion chamber + flue gas purification room (calcium hydroxide filter brick) +exhaust fan + independent chimney

10.burning temperature:

First combustion chamber: 600-800℃

Secondary combusition chamber:1500℃

Flue gas residence time≥2s

11.Combustion efficiency: ≥99.99%,

12.Incinerator during operation to ensure system is in negative pressure condition, avoid harmful gas escape;

13. Glue gas discharge standard GB18484-2001<Hazardous waste incineration pollution control standards>

 

Technical data

 

Applicable hospital size (number of beds)

150-200 beds

Burning Ability

50-100kg/time

(daily incineration 3-6 times)

Size of the incinerator

2.0×1.4×3.4m

Volume of incinerator

Gasification room1.2m3,secondary burning room 0.6m3,mixing burning room0.06m3

Size of the filling entrance

700×900mm

Chimney

Height 10m, out-radius Ø300mm

Air blower

0.75kw

Auxiliary  burner 

Power 0.11kw, oil consumption volume  10-20kg/h

Re-burning burner

power 0.22kw,oil consumption volume 7-14 kg/h

operation voltage

220V or380V

weight

About 6500kg

 

packing list

item

specification(mm)

Weight/volume

 

package

remark

main body

2300×1571700mm

4400kgs/6.1m3

1

Main body contain burner,blower,electric control cabinet etc

Second burning chamber and mixed burning 

chamber

2000x1300x1120mm

1240kgs/2.9m3

1

Contain tray height

Flue gas purification chamber 

Ø881100

480kgs/0.66m3

1

 

chimney

Ø300,height 5m

75kgs/0.35m3

1

 

oil tank

Ø600ר2000

42kgs/0.21m3

1

 

oil tank bracket

2500ר400

13kgs/0.56m3

1

 

Air hose

2100*1400*260mm

20kgs

1

 

sum:

 

6270kgs/10.78m3

7

 

 

 

 

 

 

 

 

Send Inquiry to This Supplier

Message
0/5000
Want the best price? Post an RFQ now!
Business Type
Manufacturer, Trading Company
Year Established
2003
Factory Size
3,000-5,000 square meters
Total Employees
51 - 100 People

Recommended Categories

Explore top categories and find suppliers for your specific needs