LDF series medical solid waste incinerator
LDF series medical waste incineration installation with the characteristic of small size, high efficiency and reasonable incineration, leading technology, higher harmless degree, is the ideal garbage treatment facilities apply to all kinds of hospital, hotel, station.
Design basis:
1.Furnace body type:Vertical closed furnace combustion chamber;
2. burning capacity:100-120kg/time ( daily burn 3-6times,each time consume about 1 hour)
3. Ignition manner:automatic
4.fuel type:0# or-10# diesel;
5. feeding mode:Solid waste manual feeding
6. take ash manner :manual
7. furnace inner pressure: adopt negative pressure design, no back-fire,—3~—10mmH2O
heat value: waste mix 1500kcal/kg ~2500kcal/kg,0# diesel 10000kcal/kg
9. flue gas treatment manner:
Gasification combustion chamber(first combustion chamber) + blower + mixed combustion chamber+high temperature secondary combustion chamber + flue gas purification room (calcium hydroxide filter brick) +exhaust fan + independent chimney
10.burning temperature:
First combustion chamber: 600-800℃
Secondary combusition chamber:1500℃
Flue gas residence time≥2s
11.Combustion efficiency: ≥99.99%,
12.Incinerator during operation to ensure system is in negative pressure condition, avoid harmful gas escape;
13. Glue gas discharge standard GB18484-2001<Hazardous waste incineration pollution control standards>
Main features:
1. The gasifying incineration technology to be applied to the incineration injector, feeding container and other medical equipment as well as different paper slash, bandage, cotton column, different kinds of medical pollutants and various wastes discharged by hospitals and medical organization.
2. The gasifying incineration way is utilized and the rubbished produced each day is able to handle the one-off incineration treatment.
3. The gasifying incineration, mixed incineration, burn-out treatment and other technologies are used to make the content of the smog exhaust and dust lower than the discharge standard regulated by the nation.
4. Fully seal operation is adopted to be applied to dealing with the infectious medical waste and avoid the secondary pollution.
5. Small volume and site area.
6. The series of incinerator are divided into the fuel and gas kind which can be selected according to the different needs of the users.
1.Furnace body type:Vertical closed furnace combustion chamber;
2. burning capacity:100-120kg/time ( daily burn 3-6times,each time consume about 1 hour)
3. Ignition manner:automatic
4.fuel type:0# or-10# diesel;
5. feeding mode:Solid waste manual feeding
6. take ash manner :manual
7. furnace inner pressure: adopt negative pressure design, no back-fire,—3~—10mmH2O
heat value: waste mix 1500kcal/kg ~2500kcal/kg,0# diesel 10000kcal/kg
9. flue gas treatment manner:
Gasification combustion chamber(first combustion chamber) + blower + mixed combustion chamber+high temperature secondary combustion chamber + flue gas purification room (calcium hydroxide filter brick) +exhaust fan + independent chimney
10.burning temperature:
First combustion chamber: 600-800℃
Secondary combusition chamber:1500℃
Flue gas residence time≥2s
11.Combustion efficiency: ≥99.99%,
12.Incinerator during operation to ensure system is in negative pressure condition, avoid harmful gas escape;
13. Glue gas discharge standard GB18484-2001<Hazardous waste incineration pollution control standards>
Technical data
Applicable hospital size (number of beds) | 150-200 beds |
Burning Ability | 50-100kg/time (daily incineration 3-6 times) |
Size of the incinerator | 2.0×1.4×3.4m |
Volume of incinerator | Gasification room1.2m3,secondary burning room 0.6m3,mixing burning room0.06m3 |
Size of the filling entrance | 700×900mm |
Chimney | Height 10m, out-radius Ø300mm |
Air blower | 0.75kw |
Auxiliary burner | Power 0.11kw, oil consumption volume 10-20kg/h |
Re-burning burner | power 0.22kw,oil consumption volume 7-14 kg/h |
operation voltage | 220V or380V |
weight | About 6500kg |
packing list
item | specification(mm) | Weight/volume
| package | remark |
main body | 2300×1570×1700mm | 4400kgs/6.1m3 | 1 | Main body contain burner,blower,electric control cabinet etc |
Second burning chamber and mixed burning chamber | 2000x1300x1120mm | 1240kgs/2.9m3 | 1 | Contain tray height |
Flue gas purification chamber | Ø880×1100 | 480kgs/0.66m3 | 1 |
|
chimney | Ø300,height 5m | 75kgs/0.35m3 | 1 |
|
oil tank | Ø600ר2000 | 42kgs/0.21m3 | 1 |
|
oil tank bracket | 2500ר400 | 13kgs/0.56m3 | 1 |
|
Air hose | 2100*1400*260mm | 20kgs | 1 |
|
sum: |
| 6270kgs/10.78m3 | 7 |
Send Inquiry to This Supplier
You May Also Like
-
Water Bath SterilizerNegotiableMOQ: 1 Set
-
Commercial-Grade Compost Machine for Agricultural and Horticultural Waste ManagementNegotiableMOQ: 1 Set
-
Replaceable Knives Wood Chipper Digital Maximize Efficiency for BiomassNegotiableMOQ: 1 Set
-
M931 Pex Plastic Water Ice LineNegotiableMOQ: 1
-
Nickel-Iron FoamNegotiableMOQ: 10 Square Miles
-
Refuse IncineratorUS$ 5900 - 25000MOQ: 1 Piece
-
Portable Foam Wall Chemical Oil Proof 750 Gallon Flexible Pvc Spill Containment BermNegotiableMOQ: 1
-
More Than 20 Years Factory Supply Plastic Baler MachineNegotiableMOQ: 1 Set
-
Plastic To Oil Pyrolysis Plant (Continuous Type - 3TPD to 24 TPDUS$ 298,000 - 1,344,000MOQ: 1 Plant
-
Oil Drilling Cutting Waste ManagementNegotiableMOQ: 1 Set