Heatind& Cooling Temperature Controller

Heatind& Cooling Temperature Controller photo-1
Negotiable MOQ: 10 Pieces (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Place of Origin:
Jiangsu, China
Model Number:
E30
Payment & Shipping
Payment Methods:
Port of Shipment:
China port
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin Jiangsu, China
Model Number E30

Specifications

Temperature display, temperature controlling(refrigeration/heat mode),compressor start delay protection,

Temperature Controller E30

 

Temperature display, temperature controlling(refrigeration/heat mode),compressor start delay protection, it can run periodically with the on-off rate when the temperature sensor is broken. 2 defrost modes (electric heat, hot gas), 3 defrost start mode (time alternation, accumulative compressor running time, real time clock), 2 defrost end mode (timing, controlled by both temperature and time), dripping, manual defrost, 7 fan running modes(fan ahead or delay start, delay stop, temperature controlling start and stop, time controlling start and stop, always on, always off, run or stop when defrosting), sensor error alarm, one external alarm input, password, real time clock, C/F unit change.

 

Technique Index

1,Temperature display range: -50~150°C(The resolution is 0.1°C)

                            -58~302°F(The resolution is 0.1F)

2,Power supply: AC 220V±10% or AC 380V±10% 50Hz (Refer to the wiring diagram)

3,Operating environment: temperature -30°C~80°C, humidity≤85%

4,Relay contact capability: 8A/250VAC (pure resistive load)

5,Temperature sensor: NTC R25=5kΩ, B (25/50) =3470K

Operating Guide 

1, Meaning of the index lights on the panel

Index light

Name

Light

Flash

 

Temp setting

In the state of temp setting

-

 

Refrigeration

Refrigerating

Ready to refrigerate, in the state of compressor start delay protection

 

Heat

Heating

Ready to heat, in the state of compressor start delay protection

 

Defrost

Defrosting

Dripping or the state of compressor start delay protection

 

Fan

Fan running

-

 

Alarm

-

Alarm state

2,Meaning of the LED display

    The LED usually shows temperature, if it shows “SHr”, it means the temperature sensor is short, and “OPE” means the temperature sensor is open. The temperature and the alarm code (Axx) will show alternately when in the alarm state. The code is showing below:

Code

Meaning

Explanation

A11

External alarm

Alarm from external alarm signal, refer to the internal parameter code “F50”

A21

Temperature sensor error

Open or short(showing “OPE” or “SHr”)

A22

Evaporator sensor error

Open or short(showing “OPE” or “SHr” when press the key “6”). If you don’t need to use the evaporator sensor, you can use the F59 to close the alarm.

A99

Over probation time

If you have set the probation time F87, the alarm occurs when the accumulative running time is over probation time, and the controller can not work.

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer, Trading Company
Year Established
2010
Factory Size
Below 1,000 square meters
Total Employees
101 - 200 People

Recommended Categories

Explore top categories and find suppliers for your specific needs